Instantaneous power coordinated control strategy for high-speed train traction converters

Abstract To address the issues of excessive weight in Direct Current (DC)-link capacitors for high-speed train traction converters, which reduces overall power density and increases maintenance costs, an optimized control strategy is proposed. Conventional rectifier-inverter independent control proves inadequate under high-voltage/high-power, low-switching-frequency, and limited control bandwidth conditions. The proposed DC voltage based instantaneous power collaborative control strategy selects the intermediate DC voltage as an indicator of power imbalance, reflecting the relationship between rectifier-side and inverter-side power. During power mismatch events, the intermediate DC voltage fluctuates accordingly. By real-time monitoring of DC voltage variations and dynamic compensation current adjustment, this approach reduces voltage overshoot during load transients and mitigates adverse effects of power imbalance. Using the CR400AF traction converter as a case study, a hardware-in-the-loop experimental platform was established. Experimental verification demonstrates that: at steady state, the coordinated instantaneous power control strategy based on DC voltage achieves similar performance to independent control and power feed-forward control. During transients, compensation current is calculated based on instantaneous power mismatch. Under the same support capacitance value, this method exhibits significantly faster dynamic response speed compared to independent control and power feed-forward control. It effectively suppresses DC voltage spikes during transients, allowing the DC bus voltage to quickly recover to near the reference value. After reducing the support capacitance value, this method can still maintain good dynamic response performance. The findings provide reference for optimizing control strategies to achieve lightweight support capacitors in the DC-link of traction converters.

Authors

Institutions

Publication Details

Journal
Transportation Safety and Environment
Published
2026-01-05
DOI
https://doi.org/10.1093/tse/tdaf079
Primary Topic
Railway Systems and Energy Efficiency
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Instantaneous power coordinated control strategy for high-speed train traction converters

Hao Ding, Zhuoxin Li, Jin Huang, Chaoqun Xiang
Transportation Safety and Environment
Railway Systems and Energy Efficiency
article

Instantaneous power coordinated control strategy for high-speed train traction converters

Hao Ding, Zhuoxin Li, Jin Huang, Chaoqun Xiang
article en

Abstract

Abstract To address the issues of excessive weight in Direct Current (DC)-link capacitors for high-speed train traction converters, which reduces overall power density and increases maintenance costs, an optimized control strategy is proposed. Conventional rectifier-inverter independent control proves inadequate under high-voltage/high-power, low-switching-frequency, and limited control bandwidth conditions. The proposed DC voltage based instantaneous power collaborative control strategy selects the intermediate DC voltage as an indicator of power imbalance, reflecting the relationship between rectifier-side and inverter-side power. During power mismatch events, the intermediate DC voltage fluctuates accordingly. By real-time monitoring of DC voltage variations and dynamic compensation current adjustment, this approach reduces voltage overshoot during load transients and mitigates adverse effects of power imbalance. Using the CR400AF traction converter as a case study, a hardware-in-the-loop experimental platform was established. Experimental verification demonstrates that: at steady state, the coordinated instantaneous power control strategy based on DC voltage achieves similar performance to independent control and power feed-forward control. During transients, compensation current is calculated based on instantaneous power mismatch. Under the same support capacitance value, this method exhibits significantly faster dynamic response speed compared to independent control and power feed-forward control. It effectively suppresses DC voltage spikes during transients, allowing the DC bus voltage to quickly recover to near the reference value. After reducing the support capacitance value, this method can still maintain good dynamic response performance. The findings provide reference for optimizing control strategies to achieve lightweight support capacitors in the DC-link of traction converters.

Transportation Safety and Environment
Central South University (CN), China Academy of Railway Sciences (CN)
Affordable and clean energy
Openalex Percentile: Top 96%
Railway Systems and Energy Efficiency
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.