Water-Jet Assisted Liposuction in Lipedema: Which Cannula is the Safest?

Background: Liposuction in lipedema is a safe and effective treatment, but there currently are no studies analyzing the individual complications of water-jet-assisted liposuction in lipedema or the impact of the cannula’s design. Objectives: The aim of the authors of this study is to answer the question which WAL cannula is the safest in lipedema patients and provide practitioners with the data they need to make an informed decision about the cannula they choose. Methods: The authors retrospectively analyzed complications and their underlying risk factors in 117 patients across 243 cases. Groups were formed by diameter (Ø) and number of ports of the used cannulas. Unpaired t-tests, Fisher’s exact tests, and χ2 tests were used to analyze the patients’ characteristics for the complication rates across the cannulas. Results: Cannulas with 8 ports showed statistically significantly higher hemoglobin loss (P = .011), shorter incision-to-suture time (P = .023), and higher volume of aspirated fat (P < .001). The same results occurred when comparing the Ø3.8 mm cannulas that differ in the number of ports (4 vs 8 ports). The Ø4.8 mm group showed a significantly increased rate of wound-healing disorders compared with the Ø3.8 mm group (P = .041) and a statistically significantly higher aspirated fat volume (P = .014). Conclusions: No specific cannula showed superior safety in terms of complication rates. However, 8-port cannulas facilitated a faster aspiration of large volumes and reduced the incision-to-suture time compared with 4-port cannulas. This benefit was accompanied by a greater loss of hemoglobin. In contrast, cannula diameter played a less significant role in aspiration speed and did not increase the hemoglobin loss.

Authors

Publication Details

Journal
Universitäts- und Landesbibliothek Münster
Published
2025-09-26
DOI
https://doi.org/10.17879/60968680449
Primary Topic
Lymphatic System and Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Water-Jet Assisted Liposuction in Lipedema: Which Cannula is the Safest?

Matthias Michael Aitzetmüller-Klietz, Jonah R. Berg, Tobias Hirsch, Marie-Luise Aitzetmüller-Klietz
Universitäts- und Landesbibliothek Münster
Lymphatic System and Diseases
article

Water-Jet Assisted Liposuction in Lipedema: Which Cannula is the Safest?

Matthias Michael Aitzetmüller-Klietz, Jonah R. Berg, Tobias Hirsch, Marie-Luise Aitzetmüller-Klietz
article en

Abstract

Background: Liposuction in lipedema is a safe and effective treatment, but there currently are no studies analyzing the individual complications of water-jet-assisted liposuction in lipedema or the impact of the cannula’s design. Objectives: The aim of the authors of this study is to answer the question which WAL cannula is the safest in lipedema patients and provide practitioners with the data they need to make an informed decision about the cannula they choose. Methods: The authors retrospectively analyzed complications and their underlying risk factors in 117 patients across 243 cases. Groups were formed by diameter (Ø) and number of ports of the used cannulas. Unpaired t-tests, Fisher’s exact tests, and χ2 tests were used to analyze the patients’ characteristics for the complication rates across the cannulas. Results: Cannulas with 8 ports showed statistically significantly higher hemoglobin loss (P = .011), shorter incision-to-suture time (P = .023), and higher volume of aspirated fat (P < .001). The same results occurred when comparing the Ø3.8 mm cannulas that differ in the number of ports (4 vs 8 ports). The Ø4.8 mm group showed a significantly increased rate of wound-healing disorders compared with the Ø3.8 mm group (P = .041) and a statistically significantly higher aspirated fat volume (P = .014). Conclusions: No specific cannula showed superior safety in terms of complication rates. However, 8-port cannulas facilitated a faster aspiration of large volumes and reduced the incision-to-suture time compared with 4-port cannulas. This benefit was accompanied by a greater loss of hemoglobin. In contrast, cannula diameter played a less significant role in aspiration speed and did not increase the hemoglobin loss.

Universitäts- und Landesbibliothek Münster
Clean water and sanitation
Openalex Percentile: Top 29%
Lymphatic System and Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.