Investigating the effects of spring-loaded knee brace stiffness on gait biomechanics through predictive simulation

This study aims to elucidate the biomechanical effects of varying spring‐loaded knee brace (SLKB) stiffness on knee joint mechanics. This study combined musculoskeletal modeling with a direct collocation optimal control framework to perform a predictive simulation of walking under varied SLKB stiffness (0–1.0 Nm/deg), walking speeds (1.1–1.5 m/s), and slopes (level, 5°/10° uphill and downhill). A multi‐term cost function minimized metabolic energy, muscle activation rates, actuator excitations, joint accelerations, and joint‐limit penalties, yielding physiologically realistic trajectories that satisfied dynamic, path, and boundary constraints. Low‐stiffness SLKBs closely matched the no‐brace baseline, whereas increasing stiffness progressively restricted knee range of motion, induced minimal ground reaction force changes except under incline conditions, elevated knee flexor activations (biceps femoris, lateral gastrocnemius) for foot clearance, and reduced vastus medialis activity during inclined and declined walking. Crucially, medium to high‐stiffness SLKBs produced consistent early‐stance unloading of the knee vertical joint reaction force—up to 29.3% reduction uphill and 23.6% reduction downhill—although unloading effects attenuated or reversed in mid‐ and late‐stance. Increasing SLKB stiffness influenced knee kinematics and muscle activations, with phase‑ and condition‑dependent unloading effects, particularly during uphill walking. These findings suggest potential benefits for knee osteoarthritis, warranting in vivo validation and the development of subject‐specific, condition‑adaptive designs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-07
DOI
https://doi.org/10.1038/s41598-025-33424-6
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigating the effects of spring-loaded knee brace stiffness on gait biomechanics through predictive simulation

Huihao Wang, Xiaoyue Hu, X Chen, Zhang Li et al.
Scientific Reports
Prosthetics and Rehabilitation Robotics
article

Investigating the effects of spring-loaded knee brace stiffness on gait biomechanics through predictive simulation

Huihao Wang, Xiaoyue Hu, X Chen, Zhang Li, Kuan Wang, Leichao Liang
article en

Abstract

This study aims to elucidate the biomechanical effects of varying spring‐loaded knee brace (SLKB) stiffness on knee joint mechanics. This study combined musculoskeletal modeling with a direct collocation optimal control framework to perform a predictive simulation of walking under varied SLKB stiffness (0–1.0 Nm/deg), walking speeds (1.1–1.5 m/s), and slopes (level, 5°/10° uphill and downhill). A multi‐term cost function minimized metabolic energy, muscle activation rates, actuator excitations, joint accelerations, and joint‐limit penalties, yielding physiologically realistic trajectories that satisfied dynamic, path, and boundary constraints. Low‐stiffness SLKBs closely matched the no‐brace baseline, whereas increasing stiffness progressively restricted knee range of motion, induced minimal ground reaction force changes except under incline conditions, elevated knee flexor activations (biceps femoris, lateral gastrocnemius) for foot clearance, and reduced vastus medialis activity during inclined and declined walking. Crucially, medium to high‐stiffness SLKBs produced consistent early‐stance unloading of the knee vertical joint reaction force—up to 29.3% reduction uphill and 23.6% reduction downhill—although unloading effects attenuated or reversed in mid‐ and late‐stance. Increasing SLKB stiffness influenced knee kinematics and muscle activations, with phase‑ and condition‑dependent unloading effects, particularly during uphill walking. These findings suggest potential benefits for knee osteoarthritis, warranting in vivo validation and the development of subject‐specific, condition‑adaptive designs.

Scientific ReportsVol. 16(1)
The University of Queensland (AU), Second Military Medical University (CN), Shanghai University of Traditional Chinese Medicine (CN), Shanghai University of Medicine and Health Sciences (CN), Shuguang Hospital (CN), Shanghai Pudong New Area Gongli Hospital (CN)
Natural Science Foundation of Shanghai, Shanghai Municipal Health Commission, National Natural Science Foundation of China, Shanghai University of Medicine and Health Sciences
Affordable and clean energy
Openalex Percentile: Top 96%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.