Evaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods

We compared scatter correction (SC) in single-photon emission computed tomography (SPECT) images using effective scatter source estimation (ESSE) and the triple-energy window (TEW) method. We acquired 99mTc and 123I images of brain, myocardial, and performance phantoms containing rods with different diameters. We assessed contrast ratios (CRs) and ROI-based noise metrics (coefficient of variation, signal-to-noise ratio, and contrast-to-noise ratio [CNR] ). Under 99mTc, ESSE yielded higher CRs than TEW across all phantoms (mean difference 0.04, range 0.01–0.05) and produced the highest CNR in the myocardial phantom, improving the conspicuousness of the simulated defect. Under 123I, CR differences between ESSE and TEW were small and inconsistent (performance phantom: −0.04 to 0.06; brain phantom: −0.01 to 0.00). A Monte Carlo simulation (point source in air) showed substantial photopeak window penetration for cardiac high-resolution collimators (40.0%) but low penetration for medium-energy general-purpose collimators (5.1%), supporting photopeak contamination as a contributor to the 123I findings and potentially attenuating the apparent advantage of model-based SC that does not explicitly account for penetration photons. These findings suggest that SC selection should consider the radionuclide and imaging target and that ESSE might be a reasonable option for 99mTc myocardial imaging under the settings examined.

Authors

Institutions

Publication Details

Journal
Radiation
Published
2026-01-07
DOI
https://doi.org/10.3390/radiation6010001
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods

Shota Hosokawa, Tomoya Okamoto, Koichi Okuda, Yasuyuki Takahashi et al.
Radiation
Medical Imaging Techniques and Applications
article

Evaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods

Shota Hosokawa, Tomoya Okamoto, Koichi Okuda, Yasuyuki Takahashi, Yoshihisa Niioka, Masakatsu Tsurugaya, Kazuya Tsushima, Ryutaro Mori
article en

Abstract

We compared scatter correction (SC) in single-photon emission computed tomography (SPECT) images using effective scatter source estimation (ESSE) and the triple-energy window (TEW) method. We acquired 99mTc and 123I images of brain, myocardial, and performance phantoms containing rods with different diameters. We assessed contrast ratios (CRs) and ROI-based noise metrics (coefficient of variation, signal-to-noise ratio, and contrast-to-noise ratio [CNR] ). Under 99mTc, ESSE yielded higher CRs than TEW across all phantoms (mean difference 0.04, range 0.01–0.05) and produced the highest CNR in the myocardial phantom, improving the conspicuousness of the simulated defect. Under 123I, CR differences between ESSE and TEW were small and inconsistent (performance phantom: −0.04 to 0.06; brain phantom: −0.01 to 0.00). A Monte Carlo simulation (point source in air) showed substantial photopeak window penetration for cardiac high-resolution collimators (40.0%) but low penetration for medium-energy general-purpose collimators (5.1%), supporting photopeak contamination as a contributor to the 123I findings and potentially attenuating the apparent advantage of model-based SC that does not explicitly account for penetration photons. These findings suggest that SC selection should consider the radionuclide and imaging target and that ESSE might be a reasonable option for 99mTc myocardial imaging under the settings examined.

RadiationVol. 6(1)
Hirosaki University (JP), Iwaki Kyoritsu General Hospital (JP)
Affordable and clean energy
Openalex Percentile: Top 96%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Scatter Correction Methods in SPECT Images: A Phantom-Based Study of TEW and ESSE Methods — Shota Hosokawa, Tomoya Okamoto, et al. · Radiation (2026) | TGRS Research Map | TGRS