Direct Detection of Volatile Organic Compounds through Cationization Using ICP-MS/MS

We have developed a new analytical technique for the detection of volatile organic compounds (VOCs) using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). Eight VOCs of various polarities (acetic acid, 2-butanone, pyridine, 2-methylfuran, ethylene, benzene, toluene, and limonene) were introduced into the collision/reaction cell (CRC) of the ICP-MS/MS, bypassing the ICP ion source. This approach enabled a softer ionization than the typical ICP, allowing the detection of the molecules in their intact form. In this study, to explore the potential of cationization as a soft ionization approach, the interaction of the above VOCs with various elements (<i>i.e</i>., Li, Be, Na, Mg, V, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Ru, Pd, Ag, Cd, Cs, Ba, Pt, and Hg) was investigated. The production ratio of cation adducts was evaluated using benzene as a model compound by monitoring [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> values (E represents each element). The resulting [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> showed a wide variation, covering ranges from 0.0001% to 1%, and the elements with ionization energies between 650 and 900 kJ mol<sup>-1</sup> exhibited the highest [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> values. The data obtained here revealed that several elements, including Co, Ni, Cu, Ru, Pd, and Ag, can be suitable elements for cationization. The reduction in fragmentation resulted in easier detection of specific compounds based on their <i>m</i>/<i>z</i> values. To demonstrate the practicality of the present technique, several VOCs released from coffee beans through laser-induced evaporation were monitored. The data obtained here envisage a possibility that the detection of VOCs through cationization achieved in ICP-MS/MS can become an effective choice as a rapid analytical tool for VOCs in solid samples.

Authors

Institutions

Publication Details

Journal
Mass Spectrometry
Published
2026-01-06
DOI
https://doi.org/10.5702/massspectrometry.a0187
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Direct Detection of Volatile Organic Compounds through Cationization Using ICP-MS/MS

Takafumi Hirata, Hui Hsin Khoo, Maki Uezono, Chihaya Kinoshita
Mass Spectrometry
Advanced Chemical Sensor Technologies
article

Direct Detection of Volatile Organic Compounds through Cationization Using ICP-MS/MS

Takafumi Hirata, Hui Hsin Khoo, Maki Uezono, Chihaya Kinoshita
article en

Abstract

We have developed a new analytical technique for the detection of volatile organic compounds (VOCs) using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS). Eight VOCs of various polarities (acetic acid, 2-butanone, pyridine, 2-methylfuran, ethylene, benzene, toluene, and limonene) were introduced into the collision/reaction cell (CRC) of the ICP-MS/MS, bypassing the ICP ion source. This approach enabled a softer ionization than the typical ICP, allowing the detection of the molecules in their intact form. In this study, to explore the potential of cationization as a soft ionization approach, the interaction of the above VOCs with various elements (<i>i.e</i>., Li, Be, Na, Mg, V, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Ru, Pd, Ag, Cd, Cs, Ba, Pt, and Hg) was investigated. The production ratio of cation adducts was evaluated using benzene as a model compound by monitoring [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> values (E represents each element). The resulting [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> showed a wide variation, covering ranges from 0.0001% to 1%, and the elements with ionization energies between 650 and 900 kJ mol<sup>-1</sup> exhibited the highest [C<sub>6</sub>H<sub>6</sub> + E]<sup>+</sup>/E<sup>+</sup> values. The data obtained here revealed that several elements, including Co, Ni, Cu, Ru, Pd, and Ag, can be suitable elements for cationization. The reduction in fragmentation resulted in easier detection of specific compounds based on their <i>m</i>/<i>z</i> values. To demonstrate the practicality of the present technique, several VOCs released from coffee beans through laser-induced evaporation were monitored. The data obtained here envisage a possibility that the detection of VOCs through cationization achieved in ICP-MS/MS can become an effective choice as a rapid analytical tool for VOCs in solid samples.

Mass SpectrometryVol. 15(1)
The University of Tokyo (JP)
Ministry of Education, Culture, Sports, Science and Technology
Openalex Percentile: Top 96%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.