Foreign Body Reaction in Wrist Arthroplasty Using a Carbon Fiber Reinforced Poly-Ether-Ether-Ketone Articulation: A Secondary Analysis of 11 Cases

Abstract Wrist arthroplasty is a motion-preserving procedure. However, despite improvements in implant design, implant failure remains an issue. The aim of this secondary analysis was to assess failures associated with synovitis and to report histopathological findings in an initial patient cohort (n = 40) reported previously. Eleven cases of implant failure and synovitis were identified among hemi and total wrist arthroplasties with a carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) articulation. Six cases had undergone component exchange/revision; of these, five were revised to a radiocarpal arthrodesis. Pronounced wear of the CFR-PEEK articulating surface was noted. Histopathological examination indicated that CFR-PEEK particles were incorporated by macrophages, but no giant cell reactions could be seen. A high frequency of synovitis warranting reoperation was noted. We recommend caution and close monitoring of CFR-PEEK articulations in the wrist.

Authors

Institutions

Publication Details

Journal
Journal of Wrist Surgery
Published
2026-01-07
DOI
https://doi.org/10.1055/a-2776-0671
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Foreign Body Reaction in Wrist Arthroplasty Using a Carbon Fiber Reinforced Poly-Ether-Ether-Ketone Articulation: A Secondary Analysis of 11 Cases

Marcus Sagerfors, Per Wretenberg, A Szállaśi, Daniel Reiser et al.
Journal of Wrist Surgery
Orthopedic Surgery and Rehabilitation
article

Foreign Body Reaction in Wrist Arthroplasty Using a Carbon Fiber Reinforced Poly-Ether-Ether-Ketone Articulation: A Secondary Analysis of 11 Cases

Marcus Sagerfors, Per Wretenberg, A Szállaśi, Daniel Reiser, Severin Sape
article en

Abstract

Abstract Wrist arthroplasty is a motion-preserving procedure. However, despite improvements in implant design, implant failure remains an issue. The aim of this secondary analysis was to assess failures associated with synovitis and to report histopathological findings in an initial patient cohort (n = 40) reported previously. Eleven cases of implant failure and synovitis were identified among hemi and total wrist arthroplasties with a carbon fiber reinforced poly-ether-ether-ketone (CFR-PEEK) articulation. Six cases had undergone component exchange/revision; of these, five were revised to a radiocarpal arthrodesis. Pronounced wear of the CFR-PEEK articulating surface was noted. Histopathological examination indicated that CFR-PEEK particles were incorporated by macrophages, but no giant cell reactions could be seen. A high frequency of synovitis warranting reoperation was noted. We recommend caution and close monitoring of CFR-PEEK articulations in the wrist.

Journal of Wrist Surgery
Semmelweis University (HU), Örebro University (SE), Örebro County Council (SE), Örebro University Hospital (SE)
Openalex Percentile: Top 96%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines