Accuracy of Freehand External Ventricular Drainage Catheter Placement and Technical Insight

Abstract Freehand external ventricular drainage (EVD) remains widely used in emergent settings, but its accuracy and optimal parameters (Kocher's point, trajectory angle, and catheter length) remain variable in neurosurgical practice. We conducted a retrospective study from January to December 2023 that included all patients who required an EVD for hydrocephalus. We excluded pediatric patients with abnormal head shapes. We analyzed Kocher's point, EVD angulation, and EVD length relative to optimal placement (ipsilateral frontal horn). Univariable and multivariable logistic regression were used to identify independent predictors of suboptimal catheter tip position. Receiver operating characteristic (ROC) curve/area under the curve (AUC) and Youden's index identified optimal cut-points for catheter length. We also explored technical factors associated with optimal placement. Sixty-one EVD insertions met the inclusion criteria, out of which 70.5% (43/61) achieved optimal placement. On multivariable logistic regression, only intracranial catheter length independently predicted suboptimal placement (odds ratio [OR]: 13.84/cm; 95% confidence interval [CI]: 2.99–64.01; p = 0.001). Model performance was strong (Nagelkerke's R 2 = 0.552; Hosmer–Lemeshow p = 0.382). EVD length showed excellent discrimination (AUC: 0.867; 95% CI: 0.78–0.94). The Youden cut-point was 6.5 cm (sensitivity, 82%; specificity, 78%); a conservative clinical threshold of 5.5 cm maintained high sensitivity with added safety against over-insertion. Kocher's point combinations of 1 to 1.5 cm anterior to the coronal suture and 3 to 3.5 cm lateral to the midline were most frequently associated with optimal placement but were not statistically significant. Freehand frontal EVD insertion achieved accuracy within ranges reported for neuronavigated techniques, provided Kocher's point, trajectory, and catheter length fall within the specified parameters.

Authors

Institutions

Publication Details

Journal
Indian Journal of Neurosurgery
Published
2026-01-07
DOI
https://doi.org/10.1055/s-0045-1814453
Primary Topic
Cerebrospinal fluid and hydrocephalus
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accuracy of Freehand External Ventricular Drainage Catheter Placement and Technical Insight

Amritpal Singh Sidhu, Donald Ngian-San Liew, Siew-Hong Yiek, Albert Sii-Hieng Wong
Indian Journal of Neurosurgery
Cerebrospinal fluid and hydrocephalus
article

Accuracy of Freehand External Ventricular Drainage Catheter Placement and Technical Insight

Amritpal Singh Sidhu, Donald Ngian-San Liew, Siew-Hong Yiek, Albert Sii-Hieng Wong
article en

Abstract

Abstract Freehand external ventricular drainage (EVD) remains widely used in emergent settings, but its accuracy and optimal parameters (Kocher's point, trajectory angle, and catheter length) remain variable in neurosurgical practice. We conducted a retrospective study from January to December 2023 that included all patients who required an EVD for hydrocephalus. We excluded pediatric patients with abnormal head shapes. We analyzed Kocher's point, EVD angulation, and EVD length relative to optimal placement (ipsilateral frontal horn). Univariable and multivariable logistic regression were used to identify independent predictors of suboptimal catheter tip position. Receiver operating characteristic (ROC) curve/area under the curve (AUC) and Youden's index identified optimal cut-points for catheter length. We also explored technical factors associated with optimal placement. Sixty-one EVD insertions met the inclusion criteria, out of which 70.5% (43/61) achieved optimal placement. On multivariable logistic regression, only intracranial catheter length independently predicted suboptimal placement (odds ratio [OR]: 13.84/cm; 95% confidence interval [CI]: 2.99–64.01; p = 0.001). Model performance was strong (Nagelkerke's R 2 = 0.552; Hosmer–Lemeshow p = 0.382). EVD length showed excellent discrimination (AUC: 0.867; 95% CI: 0.78–0.94). The Youden cut-point was 6.5 cm (sensitivity, 82%; specificity, 78%); a conservative clinical threshold of 5.5 cm maintained high sensitivity with added safety against over-insertion. Kocher's point combinations of 1 to 1.5 cm anterior to the coronal suture and 3 to 3.5 cm lateral to the midline were most frequently associated with optimal placement but were not statistically significant. Freehand frontal EVD insertion achieved accuracy within ranges reported for neuronavigated techniques, provided Kocher's point, trajectory, and catheter length fall within the specified parameters.

Indian Journal of Neurosurgery
Sarawak General Hospital (MY), University of Malaya (MY)
Reduced inequalities
Openalex Percentile: Top 96%
Cerebrospinal fluid and hydrocephalus
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.