Field uniformity enhancement in a prototype high-temperature superconducting dipole magnet

High-temperature superconducting (HTS) magnets are applied across MRI, NMR, and fusion, and particle accelerators are likewise advancing toward higher magnetic fields, creating a need for high-field magnets. In synchrotrons, high-field dipole magnets of saddle geometry are required, and REBCO has drawn attention as a promising material to realize them. For these applications, the magnetic field must be spatially homogeneous along the beam line and temporally stable. However, for REBCO dipole magnets, there are few studies that rigorously report field uniformity and temporal stability on the beam line, and efforts to improve the uniformity itself remain scarce. Here we demonstrate improved field uniformity in a conduction-cooled, no-insulation (NI) REBCO saddle dipole magnet engineered to produce a 0.5 T central field. Two strategies to mitigate magnetic field uniformity due to screening-current-induced field (SCIF) or fabrication errors were assessed: current sweep reversal (CSR) and passive shimming using an AISI 1008 ferroshim. CSR produced ∼0.4× [Formula: see text] of improvement in spatial uniformity, while the ferroshim improved uniformity 4.5× [Formula: see text]. Harmonics are sextupole-dominant with small skew residuals, and temporal drift is ≤0.38× [Formula: see text] [Formula: see text]. Our results demonstrate the impact of each magnetic-field improvement technique on field uniformity using numerical simulations and experimental validations. These results outline a practical route to low-temperature-superconducting(LTS)-class field uniformity in a compact and cryogen-free dipole magnet with the NI HTS technique.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-07
DOI
https://doi.org/10.1038/s41598-025-33641-z
Primary Topic
Physics of Superconductivity and Magnetism
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field uniformity enhancement in a prototype high-temperature superconducting dipole magnet

Hongmin Yang, Garam Hahn, W. Jung, Junsu Kim et al.
Scientific Reports
Physics of Superconductivity and Magnetism
article

Field uniformity enhancement in a prototype high-temperature superconducting dipole magnet

Hongmin Yang, Garam Hahn, W. Jung, Junsu Kim, Geonyoung Kim, Minchul Ahn, Yufan Yan, Jeseok Bang, Jeonghwan Park, Seungyong Hahn, Hyoungku Kang, Prof. Seyong Choi, Hyunsoo Park
article en

Abstract

High-temperature superconducting (HTS) magnets are applied across MRI, NMR, and fusion, and particle accelerators are likewise advancing toward higher magnetic fields, creating a need for high-field magnets. In synchrotrons, high-field dipole magnets of saddle geometry are required, and REBCO has drawn attention as a promising material to realize them. For these applications, the magnetic field must be spatially homogeneous along the beam line and temporally stable. However, for REBCO dipole magnets, there are few studies that rigorously report field uniformity and temporal stability on the beam line, and efforts to improve the uniformity itself remain scarce. Here we demonstrate improved field uniformity in a conduction-cooled, no-insulation (NI) REBCO saddle dipole magnet engineered to produce a 0.5 T central field. Two strategies to mitigate magnetic field uniformity due to screening-current-induced field (SCIF) or fabrication errors were assessed: current sweep reversal (CSR) and passive shimming using an AISI 1008 ferroshim. CSR produced ∼0.4× [Formula: see text] of improvement in spatial uniformity, while the ferroshim improved uniformity 4.5× [Formula: see text]. Harmonics are sextupole-dominant with small skew residuals, and temporal drift is ≤0.38× [Formula: see text] [Formula: see text]. Our results demonstrate the impact of each magnetic-field improvement technique on field uniformity using numerical simulations and experimental validations. These results outline a practical route to low-temperature-superconducting(LTS)-class field uniformity in a compact and cryogen-free dipole magnet with the NI HTS technique.

Scientific ReportsVol. 16(1)
Florida State University (US), Korea National University of Transportation (KR), Kunsan National University (KR), Pohang University of Science and Technology (KR), Seoul National University (KR), Lawrence Berkeley National Laboratory (US), Kangwon National University (KR), Korea Electric Power Corporation (South Korea) (KR), Korea Research Institute of Standards and Science (KR), National University College (PR), National High Magnetic Field Laboratory (US), Korea Basic Science Institute (KR)
National Research Foundation, Seoul National University, National Research Foundation of Korea, Ministry of Science and ICT, South Korea
Openalex Percentile: Top 93%
Physics of Superconductivity and Magnetism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.