Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation

Photon-counting CT (PCCT) is the mainstay of multi-spectral imaging, enabling quantitative tissue characterization. In radiation oncology, cone-beam CT is used daily for image-guided and online-adaptive radiotherapy. The novel HyperSight cone-beam CT imaging mode (CBCT), with enhanced image quality due in part to its enlarged detector size and optimized reconstruction modes, further facilitates quantitative image monitoring and high-precision radiotherapy. Integrating spectral PCCT information may further amplify its potential. Therefore, this study investigates whether qualitative and spectral quantitative PCCT-parameters can be translated to CBCT. An inorganic tissue-equivalent anthropomorphic phantom analysis was conducted using CBCT (iCBCT/iCBCT Acuros reconstruction, Pelvis/Pelvis Large preset) and PCCT (T3D (polychromatic reconstruction) with virtual monochromatic imaging (VMI)). Twenty regions with different CT numbers were assessed qualitatively and quantitatively. Image quality was highest for T3D PCCT. Quantitative analysis showed stronger agreement between CBCT (iCBCT Acuros) and PCCT-derived 60 and 67 keV VMI (concordance correlation coefficient (CCC) ≥ 0.595), compared to T3D (CCC ≤ 0.183), with CCC values significantly affected by CBCT presets and reconstruction method (p ≤ 0.001). Machine learning-based hierarchical clustering confirmed alignment between CBCT and PCCT-based VMI, but not T3D. This successful translatability of specific VMI levels paves the way for the integration of multi-spectral imaging into high-precision CBCT-based radiotherapy using PCCT.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-08
DOI
https://doi.org/10.1038/s41598-025-33888-6
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation

Jens Fleckenstein, Victor Siefert, Stefan Sawall, Constantin Dreher et al.
Scientific Reports
Advanced X-ray and CT Imaging
article

Multispectral PCCT and CBCT imaging for high precision radiotherapy through translation of imaging parameters with machine learning validation

Jens Fleckenstein, Victor Siefert, Stefan Sawall, Constantin Dreher, Abhinay Vellala, Sven Clausen, Stefan O. Schoenberg, Frank A. Giordano, Matthias Froelich, Florian Haag, Judit Boda-Heggemann
article en

Abstract

Photon-counting CT (PCCT) is the mainstay of multi-spectral imaging, enabling quantitative tissue characterization. In radiation oncology, cone-beam CT is used daily for image-guided and online-adaptive radiotherapy. The novel HyperSight cone-beam CT imaging mode (CBCT), with enhanced image quality due in part to its enlarged detector size and optimized reconstruction modes, further facilitates quantitative image monitoring and high-precision radiotherapy. Integrating spectral PCCT information may further amplify its potential. Therefore, this study investigates whether qualitative and spectral quantitative PCCT-parameters can be translated to CBCT. An inorganic tissue-equivalent anthropomorphic phantom analysis was conducted using CBCT (iCBCT/iCBCT Acuros reconstruction, Pelvis/Pelvis Large preset) and PCCT (T3D (polychromatic reconstruction) with virtual monochromatic imaging (VMI)). Twenty regions with different CT numbers were assessed qualitatively and quantitatively. Image quality was highest for T3D PCCT. Quantitative analysis showed stronger agreement between CBCT (iCBCT Acuros) and PCCT-derived 60 and 67 keV VMI (concordance correlation coefficient (CCC) ≥ 0.595), compared to T3D (CCC ≤ 0.183), with CCC values significantly affected by CBCT presets and reconstruction method (p ≤ 0.001). Machine learning-based hierarchical clustering confirmed alignment between CBCT and PCCT-based VMI, but not T3D. This successful translatability of specific VMI levels paves the way for the integration of multi-spectral imaging into high-precision CBCT-based radiotherapy using PCCT.

Scientific ReportsVol. 16(1)
University of Mannheim (DE), German Cancer Research Center (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Central Institute of Mental Health (DE), University Medical Centre Mannheim (DE)
Siemens Healthineers
Openalex Percentile: Top 96%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.