Integrable Post-Fabrication Annealing Treatment for Polymer-Based Capacitive Micromachined Ultrasonic Transducers: Performance Impacts

This study investigates the effects of post-fabrication annealing on polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs). These devices comprise microscopic diaphragms produced via photolithographic patterning of polymer layers. Critical point drying, required to release the diaphragms, can cause significant plastic deformation, thereby reducing electromechanical coupling. Post-fabrication annealing, carried out in incremental steps up to 190 °C, led to an effective increase in coupling by a factor of 5.4. Atomic Force Microscopy showed that the initial upward deflection of 162.7 nm decreased to 6.2 nm after annealing at 190 °C, while also improving surface uniformity. In parallel, the transducer’s resonance frequency rose from 2.33 MHz (unannealed) to 2.60 MHz, and the input impedance phase angle at resonance increased from −68.1° to −4.3°. Together, these changes indicate a significant improvement in resonator behavior and, consequently, device performance. Thus, post-fabrication annealing is an effective measure to achieve the designed performance while enhancing manufacturing yield, thereby increasing the applicability of polyCMUTs.

Authors

Institutions

Publication Details

Journal
Journal of Manufacturing and Materials Processing
Published
2026-01-06
DOI
https://doi.org/10.3390/jmmp10010017
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrable Post-Fabrication Annealing Treatment for Polymer-Based Capacitive Micromachined Ultrasonic Transducers: Performance Impacts

Jonas Welsch, Edmond Cretu, Chenyang Luo, Martin Angerer et al.
Journal of Manufacturing and Materials Processing
Ultrasound Imaging and Elastography
article

Integrable Post-Fabrication Annealing Treatment for Polymer-Based Capacitive Micromachined Ultrasonic Transducers: Performance Impacts

Jonas Welsch, Edmond Cretu, Chenyang Luo, Martin Angerer, Robert Rohling
article en

Abstract

This study investigates the effects of post-fabrication annealing on polymer-based capacitive micromachined ultrasonic transducers (polyCMUTs). These devices comprise microscopic diaphragms produced via photolithographic patterning of polymer layers. Critical point drying, required to release the diaphragms, can cause significant plastic deformation, thereby reducing electromechanical coupling. Post-fabrication annealing, carried out in incremental steps up to 190 °C, led to an effective increase in coupling by a factor of 5.4. Atomic Force Microscopy showed that the initial upward deflection of 162.7 nm decreased to 6.2 nm after annealing at 190 °C, while also improving surface uniformity. In parallel, the transducer’s resonance frequency rose from 2.33 MHz (unannealed) to 2.60 MHz, and the input impedance phase angle at resonance increased from −68.1° to −4.3°. Together, these changes indicate a significant improvement in resonator behavior and, consequently, device performance. Thus, post-fabrication annealing is an effective measure to achieve the designed performance while enhancing manufacturing yield, thereby increasing the applicability of polyCMUTs.

Journal of Manufacturing and Materials ProcessingVol. 10(1)
University of British Columbia (CA)
Government of Canada
Affordable and clean energy
Openalex Percentile: Top 97%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.