Minimal Detectable Changes by the 2-Minute Marching Test for Easy Evaluation of Cardiorespiratory Response in Youth Following COVID-19 Infection

This study aims to evaluate the reliability and minimal detectable change (MDC) of the 2 min marching test (2MMT) for cardiovascular response, as well as to compare its outcomes with those of the 6 min walk test (6MWT), in youth recovering from post-COVID-19 condition. Forty-four youth with post-COVID-19 condition underwent two assessment sessions, separated by five days, utilizing both the 6MWT and 2MMT to measure cardiorespiratory response parameters. Test–retest reliability was found to be excellent for the 6MWT (ICC = 0.83; MDC95 = 8.06%) and good for the 2MMT (ICC = 0.78; MDC95 = 15.61%) between initial and follow-up measurements. The 2MMT demonstrates good reliability and validity for assessing cardiovascular response in youth with post-COVID-19 condition. The reported MDC values provide clinically meaningful thresholds that enable clinicians to distinguish true changes in performance from measurement error. These findings support the use of the 2MMT as a practical tool for clinical assessment, providing preliminary guidance for interpreting changes in performance. However, longitudinal monitoring of patient progress was not directly assessed in this study.

Authors

Institutions

Publication Details

Journal
COVID
Published
2026-01-08
DOI
https://doi.org/10.3390/covid6010016
Primary Topic
Cardiovascular and exercise physiology
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimal Detectable Changes by the 2-Minute Marching Test for Easy Evaluation of Cardiorespiratory Response in Youth Following COVID-19 Infection

Sirima Wongphon, Noppharath Sangkarit, Patchareeya Amput, Weerasak Tapanya
COVID
Cardiovascular and exercise physiology
article

Minimal Detectable Changes by the 2-Minute Marching Test for Easy Evaluation of Cardiorespiratory Response in Youth Following COVID-19 Infection

Sirima Wongphon, Noppharath Sangkarit, Patchareeya Amput, Weerasak Tapanya
article en

Abstract

This study aims to evaluate the reliability and minimal detectable change (MDC) of the 2 min marching test (2MMT) for cardiovascular response, as well as to compare its outcomes with those of the 6 min walk test (6MWT), in youth recovering from post-COVID-19 condition. Forty-four youth with post-COVID-19 condition underwent two assessment sessions, separated by five days, utilizing both the 6MWT and 2MMT to measure cardiorespiratory response parameters. Test–retest reliability was found to be excellent for the 6MWT (ICC = 0.83; MDC95 = 8.06%) and good for the 2MMT (ICC = 0.78; MDC95 = 15.61%) between initial and follow-up measurements. The 2MMT demonstrates good reliability and validity for assessing cardiovascular response in youth with post-COVID-19 condition. The reported MDC values provide clinically meaningful thresholds that enable clinicians to distinguish true changes in performance from measurement error. These findings support the use of the 2MMT as a practical tool for clinical assessment, providing preliminary guidance for interpreting changes in performance. However, longitudinal monitoring of patient progress was not directly assessed in this study.

COVIDVol. 6(1)
University of Phayao (TH)
University of Phayao, Thailand Science Research and Innovation
Openalex Percentile: Top 95%
Cardiovascular and exercise physiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.