Characterization of Lubricant-Infused Surface Coatings Using a Label-Free Microwave Sensor

Lubricant-infused surfaces (LIS) provide critical advantages for biomedical applications, including reduced biofouling and enhanced device performance. However, monitoring lubricant stability and depletion in real-time remains challenging due to limitations in existing characterization methods. This study presents a novel, noninvasive, label-free microwave sensing platform utilizing a coplanar ultrawideband (UWB) slot antenna coupled with a complementary split-ring resonator (CSRR)-based multisurface passive tag to accurately assess the stability and evaporation dynamics of fluorocarbon-based lubricants, perfluorodecalin (Lub A) and perfluoroperhydrophenanthrene (Lub B), infused onto polytetrafluoroethylene (PTFE) substrates. Experimental data demonstrated a direct correlation between lubricant evaporation and shifts in sensor resonance frequency, enabling precise tracking of lubricant stability under various conditions. Lub A exhibited significant evaporation rates in open-air (20 kHz/min) compared to closed-air environments (3 kHz/min). In contrast, Lub B showed improved stability, with lower evaporation rates of 4.8 kHz/min (open-air) and 1.71 kHz/min (closed-air). Under phosphate-buffered saline (PBS), periodic frequency fluctuations indicated gas bubble formation and lubricant replacement by PBS, affirming the sensor's capability to detect complex interactions. Additionally, real-time detection of the LIS self-healing mechanism via lubricant redistribution was confirmed through distinct resonance frequency shifts. These findings highlight the sensor's effectiveness for robust, real-time evaluation of LIS performance, underscoring its potential for enhancing predictive maintenance and reliability of biomedical implants.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2026-01-06
DOI
https://doi.org/10.1021/acs.langmuir.5c05056
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of Lubricant-Infused Surface Coatings Using a Label-Free Microwave Sensor

Mehri Ziaee Bideskan, Maryam Badv, Maziar ShafieiDarabi, Amirhossein Yazdanicherati et al.
Langmuir
Microwave and Dielectric Measurement Techniques
article

Characterization of Lubricant-Infused Surface Coatings Using a Label-Free Microwave Sensor

Mehri Ziaee Bideskan, Maryam Badv, Maziar ShafieiDarabi, Amirhossein Yazdanicherati, Zahra Abbasi, Adam Junck
article en

Abstract

Lubricant-infused surfaces (LIS) provide critical advantages for biomedical applications, including reduced biofouling and enhanced device performance. However, monitoring lubricant stability and depletion in real-time remains challenging due to limitations in existing characterization methods. This study presents a novel, noninvasive, label-free microwave sensing platform utilizing a coplanar ultrawideband (UWB) slot antenna coupled with a complementary split-ring resonator (CSRR)-based multisurface passive tag to accurately assess the stability and evaporation dynamics of fluorocarbon-based lubricants, perfluorodecalin (Lub A) and perfluoroperhydrophenanthrene (Lub B), infused onto polytetrafluoroethylene (PTFE) substrates. Experimental data demonstrated a direct correlation between lubricant evaporation and shifts in sensor resonance frequency, enabling precise tracking of lubricant stability under various conditions. Lub A exhibited significant evaporation rates in open-air (20 kHz/min) compared to closed-air environments (3 kHz/min). In contrast, Lub B showed improved stability, with lower evaporation rates of 4.8 kHz/min (open-air) and 1.71 kHz/min (closed-air). Under phosphate-buffered saline (PBS), periodic frequency fluctuations indicated gas bubble formation and lubricant replacement by PBS, affirming the sensor's capability to detect complex interactions. Additionally, real-time detection of the LIS self-healing mechanism via lubricant redistribution was confirmed through distinct resonance frequency shifts. These findings highlight the sensor's effectiveness for robust, real-time evaluation of LIS performance, underscoring its potential for enhancing predictive maintenance and reliability of biomedical implants.

LangmuirVol. 42(2)
University of Calgary (CA), Engineering Software Research and Development (United States) (US), Software602 (Czechia) (CZ)
Affordable and clean energy
Openalex Percentile: Top 96%
Microwave and Dielectric Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.