Electrochemical Detection of Organophosphates Using Dual-Modal Enzyme-Based Biosensors

Exposure to organophosphates poses a threat to aquatic ecosystems and the public due to their acute toxicity. The dangers caused by organophosphates motivate the development of technologies for prompt detection. Therefore, engineering a portable and compact device that can monitor organophosphate vapors is vital. Electrochemical biosensors present a unique solution for rapid and selective detection of organophosphates, as these sensors are small and sense in real-time. Herein, this study investigates a dual-modal electrochemical system for the detection of dimethyl methylphosphonate (DMMP), a model organophosphate. The enzymes phosphotriesterase (PTE) and acetylcholinesterase (AChE) were chosen for detecting DMMP vapors, as these enzymes chemically engage with the target substrate and produce electrochemically measurable signals. These reaction-specific signals can be read using open circuit potentiometry and amperometry, which produce a turn-on/turn-off signal readout. The turn-on/turn-off signal readout demonstrates the dual-modal mechanism and serves as a complementary verification, thus circumventing the propensity for false positives typically associated with AChE-functionalized biosensors. Deep eutectic solvent films (∼20 μL) compatible with each enzyme were developed to achieve a truly field-deployable device that does not dry out during operation. The PTE- and AChE-modified biosensors yielded detection limits of 17.6 ± 8.7 and 2.5 ± 0.6 ppm, respectively. The dual-sensing device was further validated against a broader range of organophosphates, demonstrating the device's utility as a functional organophosphate sensor. A dual-modal biosensing system presents a unique approach for organophosphate vapor mapping, which results in proper agricultural stewardship.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-07
DOI
https://doi.org/10.1021/acs.analchem.5c04795
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Detection of Organophosphates Using Dual-Modal Enzyme-Based Biosensors

Jeffrey S. Erickson, Zachary T. Johnson, Joyce C. Breger, Scott A. Trammell et al.
Analytical Chemistry
Electrochemical sensors and biosensors
article

Electrochemical Detection of Organophosphates Using Dual-Modal Enzyme-Based Biosensors

Jeffrey S. Erickson, Zachary T. Johnson, Joyce C. Breger, Scott A. Trammell, Meghna Thakur, David A. Stenger, Igor L. Medintz
article en

Abstract

Exposure to organophosphates poses a threat to aquatic ecosystems and the public due to their acute toxicity. The dangers caused by organophosphates motivate the development of technologies for prompt detection. Therefore, engineering a portable and compact device that can monitor organophosphate vapors is vital. Electrochemical biosensors present a unique solution for rapid and selective detection of organophosphates, as these sensors are small and sense in real-time. Herein, this study investigates a dual-modal electrochemical system for the detection of dimethyl methylphosphonate (DMMP), a model organophosphate. The enzymes phosphotriesterase (PTE) and acetylcholinesterase (AChE) were chosen for detecting DMMP vapors, as these enzymes chemically engage with the target substrate and produce electrochemically measurable signals. These reaction-specific signals can be read using open circuit potentiometry and amperometry, which produce a turn-on/turn-off signal readout. The turn-on/turn-off signal readout demonstrates the dual-modal mechanism and serves as a complementary verification, thus circumventing the propensity for false positives typically associated with AChE-functionalized biosensors. Deep eutectic solvent films (∼20 μL) compatible with each enzyme were developed to achieve a truly field-deployable device that does not dry out during operation. The PTE- and AChE-modified biosensors yielded detection limits of 17.6 ± 8.7 and 2.5 ± 0.6 ppm, respectively. The dual-sensing device was further validated against a broader range of organophosphates, demonstrating the device's utility as a functional organophosphate sensor. A dual-modal biosensing system presents a unique approach for organophosphate vapor mapping, which results in proper agricultural stewardship.

Analytical ChemistryVol. 98(2)
United States Naval Research Laboratory (US), George Mason University (US), Naval Research Laboratory Center for Bio/Molecular Science and Engineering, United States Navy (US)
Openalex Percentile: Top 96%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.