Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level. • UBEM is powerful to predict building performance at city scale. • Integrated data sources were used to improve the UBEM input. • Hourly AMI data was analyzed and used to calibrate UBEM using a pattern-matching approach. • UBEM calibration achieved satisfactory accuracy in predicting summer peak loads. • The calibrated UBEM was used to estimate demand flexibility of buildings at the substation level.

Authors

Institutions

Publication Details

Journal
Applied Energy
Published
2026-01-07
DOI
https://doi.org/10.1016/j.apenergy.2025.127348
Primary Topic
Energy Load and Power Forecasting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of urban building energy model using smart meter data for district peak load prediction

Miguel Heleno, Han Li, Luis Rodriguez‐Garcia, Wanni Zhang et al.
Applied Energy
Energy Load and Power Forecasting
article

Calibration of urban building energy model using smart meter data for district peak load prediction

Miguel Heleno, Han Li, Luis Rodriguez‐Garcia, Wanni Zhang, Tianzhen Hong, Kaiyu Sun
article en

Abstract

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level. • UBEM is powerful to predict building performance at city scale. • Integrated data sources were used to improve the UBEM input. • Hourly AMI data was analyzed and used to calibrate UBEM using a pattern-matching approach. • UBEM calibration achieved satisfactory accuracy in predicting summer peak loads. • The calibrated UBEM was used to estimate demand flexibility of buildings at the substation level.

Applied EnergyVol. 407
Lawrence Berkeley National Laboratory (US)
Affordable and clean energy
Openalex Percentile: Top 96%
Energy Load and Power Forecasting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.