Translational Strategies for Developing and Evaluating Transcatheter Devices in Swine Heart Failure Models

Developing a therapeutic transcatheter device for cardiovascular diseases requires precise preclinical large animal models and robust evaluation methods. Three key aspects are essential for evaluating the safety and efficacy of a device: (1) types of swine heart failure models, (2) appropriate echocardiographic methods, and (3) the specific implantation approaches in swine. Common heart failure models include rapid pacing heart failure models, volume overload models, and ischemic models. Among the ischemic models, several approaches are performed to replicate the pathological conditions, such as coronary artery ligation, ameroid constrictor implantation, balloon occlusion, and coronary embolization. The optimal choice of echocardiographic method varies based on the procedure and includes transthoracic, transesophageal, intracardiac, and epicardial techniques. Echocardiographic imaging serves as an invaluable tool in both preclinical and clinical settings, providing structural and functional assessments, procedural guidance during device placement, and comprehensive evaluations of cardiac function and structural changes before and after implantation. Implantation approaches, such as trans-atrial, trans-apical, trans-septal, and trans-right pulmonary methods, each offer unique advantages and challenges. A thorough understanding of these approaches, including the orientation of the catheter tip relative to critical anatomical structures like the mitral annulus or coronary vasculature, is essential for ensuring procedural success. This review explores these aspects to contribute to the development and refinement of catheter-based cardiovascular interventions, ensuring reliability in preclinical data and successful clinical translation.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2026-01-06
DOI
https://doi.org/10.1007/s10439-025-03960-3
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Translational Strategies for Developing and Evaluating Transcatheter Devices in Swine Heart Failure Models

Kirthana Sreerangathama Suresh, Marissa Guo, Chihiro Miyagi, Daisuke Onohara
Annals of Biomedical Engineering
Cardiac Valve Diseases and Treatments
article

Translational Strategies for Developing and Evaluating Transcatheter Devices in Swine Heart Failure Models

Kirthana Sreerangathama Suresh, Marissa Guo, Chihiro Miyagi, Daisuke Onohara
article en

Abstract

Developing a therapeutic transcatheter device for cardiovascular diseases requires precise preclinical large animal models and robust evaluation methods. Three key aspects are essential for evaluating the safety and efficacy of a device: (1) types of swine heart failure models, (2) appropriate echocardiographic methods, and (3) the specific implantation approaches in swine. Common heart failure models include rapid pacing heart failure models, volume overload models, and ischemic models. Among the ischemic models, several approaches are performed to replicate the pathological conditions, such as coronary artery ligation, ameroid constrictor implantation, balloon occlusion, and coronary embolization. The optimal choice of echocardiographic method varies based on the procedure and includes transthoracic, transesophageal, intracardiac, and epicardial techniques. Echocardiographic imaging serves as an invaluable tool in both preclinical and clinical settings, providing structural and functional assessments, procedural guidance during device placement, and comprehensive evaluations of cardiac function and structural changes before and after implantation. Implantation approaches, such as trans-atrial, trans-apical, trans-septal, and trans-right pulmonary methods, each offer unique advantages and challenges. A thorough understanding of these approaches, including the orientation of the catheter tip relative to critical anatomical structures like the mitral annulus or coronary vasculature, is essential for ensuring procedural success. This review explores these aspects to contribute to the development and refinement of catheter-based cardiovascular interventions, ensuring reliability in preclinical data and successful clinical translation.

Annals of Biomedical Engineering
Nationwide Children's Hospital (US), Piedmont Atlanta Hospital (US), The Ohio State University (US)
American Heart Association, Emory University, Division of Cardiothoracic Surgery, University of Colorado School of Medicine, Anschutz Medical Campus
Good health and well-being
Openalex Percentile: Top 97%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.