Electrode balancing as a key factor in lithium-ion batteries: From fundamentals to ultrafast charging

The negative-to-positive (N/P) capacity ratio is a critical yet often overlooked parameter in lithium-ion battery (LIB) design. It strongly influences performance, safety, and long-term aging. This review highlights how the N/P ratio affects key factors such as solid electrolyte interphase (SEI) growth, lithium plating, dendrite formation, and irreversible capacity loss in liquid-electrolyte LIBs. We focus on systems using LiCo O 2 (LCO) and LiFe PO 4 (LFP) cathodes paired with graphite, as well as Li Mn 2 O 4 (LMO) and LFP cathodes paired with Li 4 Ti 5 O 12 (LTO). Studies and modeling approaches for determining the optimal N/P ratio are summarized, including its influence on electrode potential and electrochemical performance. For graphite-based cells, an N/P ratio above 1.0 is essential to minimize lithium plating and extend cycle life, whereas LTO-based cells can operate at an N/P ratio of 1.0 or lower without plating concerns. We also review simulations demonstrating how the N/P ratio impacts internal potential distribution, thermal behavior, and lithium transport. Overall, this review presents a practical framework for the engineering of next-generation lithium-ion batteries (LIBs) that facilitate ultra-fast charging capabilities, while ensuring safety and long-term durability are not compromised. • N/P ratio affects energy, cycle life, plating, dendrites, and battery safety. • Graphite anodes need N/P > 1; LTO cells can operate at or below unity. • Ultra-fast charging drives N/P toward 1, increasing lithium plating risk. • Low N/P raises energy density but accelerates degradation; high N/P aids safety. • Ag-doped graphite (Gr–Ag 0 . 5 ) operates at N/P ≈ 0.8 with 89 % retention.

Authors

Institutions

Publication Details

Journal
Journal of Power Sources
Published
2026-01-07
DOI
https://doi.org/10.1016/j.jpowsour.2025.239188
Primary Topic
Advancements in Battery Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrode balancing as a key factor in lithium-ion batteries: From fundamentals to ultrafast charging

Martin Brassard, Mohamed Djihad Bouguern, Anil Kumar M. R., Muskan Srivastava et al.
Journal of Power Sources
Advancements in Battery Materials
article

Electrode balancing as a key factor in lithium-ion batteries: From fundamentals to ultrafast charging

Martin Brassard, Mohamed Djihad Bouguern, Anil Kumar M. R., Muskan Srivastava, S. Zaki Ahmed, Jeremy I.G. Dawkins, Karim Zaghib, Thiago M.G. Selva, M.V. Venkatashamy Reddy, Ningaraju G N
article en

Abstract

The negative-to-positive (N/P) capacity ratio is a critical yet often overlooked parameter in lithium-ion battery (LIB) design. It strongly influences performance, safety, and long-term aging. This review highlights how the N/P ratio affects key factors such as solid electrolyte interphase (SEI) growth, lithium plating, dendrite formation, and irreversible capacity loss in liquid-electrolyte LIBs. We focus on systems using LiCo O 2 (LCO) and LiFe PO 4 (LFP) cathodes paired with graphite, as well as Li Mn 2 O 4 (LMO) and LFP cathodes paired with Li 4 Ti 5 O 12 (LTO). Studies and modeling approaches for determining the optimal N/P ratio are summarized, including its influence on electrode potential and electrochemical performance. For graphite-based cells, an N/P ratio above 1.0 is essential to minimize lithium plating and extend cycle life, whereas LTO-based cells can operate at an N/P ratio of 1.0 or lower without plating concerns. We also review simulations demonstrating how the N/P ratio impacts internal potential distribution, thermal behavior, and lithium transport. Overall, this review presents a practical framework for the engineering of next-generation lithium-ion batteries (LIBs) that facilitate ultra-fast charging capabilities, while ensuring safety and long-term durability are not compromised. • N/P ratio affects energy, cycle life, plating, dendrites, and battery safety. • Graphite anodes need N/P > 1; LTO cells can operate at or below unity. • Ultra-fast charging drives N/P toward 1, increasing lithium plating risk. • Low N/P raises energy density but accelerates degradation; high N/P aids safety. • Ag-doped graphite (Gr–Ag 0 . 5 ) operates at N/P ≈ 0.8 with 89 % retention.

Journal of Power SourcesVol. 667
Hôpital Saint-Michel (FR), Concordia University (CA)
Openalex Percentile: Top 96%
Advancements in Battery Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.