Mechanical Evaluation of Suture Docking Method Versus Novel Tensegrity Suture Screw in Treating Varus Posterolateral Surrogate and Cadaveric Elbow Instability
TEN devices significantly improved mechanical strength and pretensioning over conventional docking, enhancing early stability and reducing yield failure risk.
Authors
- Marilyn Janice Oentaryo (ORCID: https://orcid.org/0000-0002-1798-3379)
- Twy Yeung (ORCID: https://orcid.org/0009-0004-7822-6082)
- Christian Fang
Institutions
- University of Hong Kong (HK)
Publication Details
- Journal
- Orthopaedic Surgery
- Published
- 2026-01-05
- DOI
- https://doi.org/10.1111/os.70216
- Primary Topic
- Elbow and Forearm Trauma Treatment
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Innovation and Technology Fund