Synergistic Application of HydroDynamic contrast Recanalization and IVUS‐Guided Tip Detection‐Antegrade Dissection and Re‐Entry in CTO PCI

Antegrade percutaneous coronary intervention (PCI) for chronic total occlusions (CTOs) remains technically challenging. HydroDynamic contrast Recanalization (HDR) is a novel technique involving low-pressure, low-volume intraplaque contrast injection immediately distal to the proximal cap, with the goal of modulating plaque architecture and facilitating a polymer-jacketed guidewire advancement toward the distal true lumen. Intravascular ultrasound (IVUS) is useful in two HDR-related scenarios: first, to resolve proximal cap ambiguity and guide precise puncture; second, in cases of unsuccessful true lumen crossing, to identify extraplaque guidewire position and assist re-entry into the true lumen. We report a case of proximal left anterior descending artery CTO treated using combined HDR and tip detection-antegrade dissection and re-entry (TD-ADR). Initial HDR produced patchy Type 1 staining, generally indicating intraplaque tracking. Second and third subsequent contrast injections again demonstrated Type 1 staining; however, true lumen crossing with polymer-jacketed wires (Sion Black and Gladius EX) was unsuccessful. IVUS confirmed subintimal wire position. To avoid stiff wire escalation and maintain control, we switched to IVUS-guided TD-ADR. Spatial alignment enabled re-entry into the distal true lumen with a Conquest Pro 12 Sharpened Tip wire. A drug-eluting stent was implanted with excellent angiographic results and no complications. This case illustrates the complementary roles of HDR and TD-ADR in antegrade CTO PCI. HDR promotes early plaque modification and facilitates wiring with minimal perforation risk, but does not ensure intraplaque tracking. IVUS-guided TD-ADR offers a safe bailout when true lumen crossing fails. A stepwise, imaging-guided approach integrating both techniques may improve procedural success.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-01-05
DOI
https://doi.org/10.1002/ccd.70448
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergistic Application of HydroDynamic contrast Recanalization and IVUS‐Guided Tip Detection‐Antegrade Dissection and Re‐Entry in CTO PCI

Yoshifumi Kashima, Tsutomu Fujita, Umihiko Kaneko, Mauro Carlino
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Synergistic Application of HydroDynamic contrast Recanalization and IVUS‐Guided Tip Detection‐Antegrade Dissection and Re‐Entry in CTO PCI

Yoshifumi Kashima, Tsutomu Fujita, Umihiko Kaneko, Mauro Carlino
article en

Abstract

Antegrade percutaneous coronary intervention (PCI) for chronic total occlusions (CTOs) remains technically challenging. HydroDynamic contrast Recanalization (HDR) is a novel technique involving low-pressure, low-volume intraplaque contrast injection immediately distal to the proximal cap, with the goal of modulating plaque architecture and facilitating a polymer-jacketed guidewire advancement toward the distal true lumen. Intravascular ultrasound (IVUS) is useful in two HDR-related scenarios: first, to resolve proximal cap ambiguity and guide precise puncture; second, in cases of unsuccessful true lumen crossing, to identify extraplaque guidewire position and assist re-entry into the true lumen. We report a case of proximal left anterior descending artery CTO treated using combined HDR and tip detection-antegrade dissection and re-entry (TD-ADR). Initial HDR produced patchy Type 1 staining, generally indicating intraplaque tracking. Second and third subsequent contrast injections again demonstrated Type 1 staining; however, true lumen crossing with polymer-jacketed wires (Sion Black and Gladius EX) was unsuccessful. IVUS confirmed subintimal wire position. To avoid stiff wire escalation and maintain control, we switched to IVUS-guided TD-ADR. Spatial alignment enabled re-entry into the distal true lumen with a Conquest Pro 12 Sharpened Tip wire. A drug-eluting stent was implanted with excellent angiographic results and no complications. This case illustrates the complementary roles of HDR and TD-ADR in antegrade CTO PCI. HDR promotes early plaque modification and facilitates wiring with minimal perforation risk, but does not ensure intraplaque tracking. IVUS-guided TD-ADR offers a safe bailout when true lumen crossing fails. A stepwise, imaging-guided approach integrating both techniques may improve procedural success.

Catheterization and Cardiovascular InterventionsVol. 107(4)
Vita-Salute San Raffaele University (IT), San Raffaele University of Rome (IT), Sapporo Science Center (JP), International Tourism Institute (SI), Oita University Hospital (JP)
Openalex Percentile: Top 97%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.