A time-resolved fluorescent signal tag-mediated immunochromatographic assay for the rapid and sensitive detection of fluoxetine

The illegal addition of fluoxetine (FLX) to weight-loss products poses significant health risks to consumers. In this study, computer-aided simulation technology was utilized to design and screen FLX hapten. By optimizing the alkyl linker strategy, while preserving the structural similarity with the parent molecule, the hydrophobic interaction was enhanced, thereby significantly improving antibody performance. Based on this strategy, we successfully developed a highly sensitive monoclonal antibody (mAb). Leveraging this, we established an immunochromatographic assay (ICA) utilizing time-resolved fluorescent microspheres (TRFMs) for detecting FLX in capsule, tablet, and beverage samples, with limits of detection (LODs) of 3.010 and 1.549 µg/kg, and 0.886 ng/mL, respectively. Notably, the proposed ICA demonstrated acceptable selectivity, stability, and reproducibility. The recovery rates for FLX in the aforementioned matrices were 97.9%-101.8%, 96.9%-103.4%, and 99.1%-101.7%, respectively. These results were consistent with those obtained via LC-MS/MS. The TRFMs-based ICA provides a reliable, rapid, high-sensitivity, and real-time method for monitoring FLX levels. Moreover, this assay provides a promising strategy for the rapid detection of unauthorized non-food additives in food products. A time-resolved fluorescence immunoassay based on a highly sensitive antibody for the rapid detection of FLX. • Novel FLX haptens were designed using computational chemistry-assisted simulations. • High-performance FLX mAb were prepared using the homologous pairing antigen strategy. • A sensitive FLX ICA assay was developed, showing good specificity accuracy and stability. • The detection results of weight-loss supplements matched LC-MS/MS finding.

Authors

Institutions

Publication Details

Journal
Journal of Food Composition and Analysis
Published
2026-01-08
DOI
https://doi.org/10.1016/j.jfca.2026.108884
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A time-resolved fluorescent signal tag-mediated immunochromatographic assay for the rapid and sensitive detection of fluoxetine

Xinyu Zhang, Xiangrui Li, Qiujin Zhu, Lu Zeng et al.
Journal of Food Composition and Analysis
Biosensors and Analytical Detection
article

A time-resolved fluorescent signal tag-mediated immunochromatographic assay for the rapid and sensitive detection of fluoxetine

Xinyu Zhang, Xiangrui Li, Qiujin Zhu, Lu Zeng, Wenjia Yang
article en

Abstract

The illegal addition of fluoxetine (FLX) to weight-loss products poses significant health risks to consumers. In this study, computer-aided simulation technology was utilized to design and screen FLX hapten. By optimizing the alkyl linker strategy, while preserving the structural similarity with the parent molecule, the hydrophobic interaction was enhanced, thereby significantly improving antibody performance. Based on this strategy, we successfully developed a highly sensitive monoclonal antibody (mAb). Leveraging this, we established an immunochromatographic assay (ICA) utilizing time-resolved fluorescent microspheres (TRFMs) for detecting FLX in capsule, tablet, and beverage samples, with limits of detection (LODs) of 3.010 and 1.549 µg/kg, and 0.886 ng/mL, respectively. Notably, the proposed ICA demonstrated acceptable selectivity, stability, and reproducibility. The recovery rates for FLX in the aforementioned matrices were 97.9%-101.8%, 96.9%-103.4%, and 99.1%-101.7%, respectively. These results were consistent with those obtained via LC-MS/MS. The TRFMs-based ICA provides a reliable, rapid, high-sensitivity, and real-time method for monitoring FLX levels. Moreover, this assay provides a promising strategy for the rapid detection of unauthorized non-food additives in food products. A time-resolved fluorescence immunoassay based on a highly sensitive antibody for the rapid detection of FLX. • Novel FLX haptens were designed using computational chemistry-assisted simulations. • High-performance FLX mAb were prepared using the homologous pairing antigen strategy. • A sensitive FLX ICA assay was developed, showing good specificity accuracy and stability. • The detection results of weight-loss supplements matched LC-MS/MS finding.

Journal of Food Composition and AnalysisVol. 150
Guizhou University (CN)
Openalex Percentile: Top 96%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.