Limitations of ventricular assist devices in pediatrics: When one size does not fit all

Ventricular assist device (VAD) use in pediatric heart failure is an evolving field with increasing volume and case complexity of patients supported. Despite this, limited VADs used are developed for infants and children, with significant numbers supported using adult devices. While outcomes on support are influenced by a variety of factors, including illness severity at VAD implant, need for additional right heart support, and presence of congenital heart disease, body size remains an independent predictor of mortality and adverse events on VAD support. Those patients able to accommodate adult-designed implantable continuous-flow VADs experience markedly improved survival outcomes and lower complication rates with improved rehabilitation potential. For the remaining cohort, device choices are limited to extracorporeal VAD support with inferior outcomes and care limited to hospital settings. The deficit in pediatric-specific VAD devices is a well-recognized need to optimize care for this complex cohort.

Authors

Institutions

Publication Details

Journal
JHLT Open
Published
2026-01-07
DOI
https://doi.org/10.1016/j.jhlto.2025.100428
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limitations of ventricular assist devices in pediatrics: When one size does not fit all

Áine Lynch, Aamir Jeewa
JHLT Open
Mechanical Circulatory Support Devices
article

Limitations of ventricular assist devices in pediatrics: When one size does not fit all

Áine Lynch, Aamir Jeewa
article en

Abstract

Ventricular assist device (VAD) use in pediatric heart failure is an evolving field with increasing volume and case complexity of patients supported. Despite this, limited VADs used are developed for infants and children, with significant numbers supported using adult devices. While outcomes on support are influenced by a variety of factors, including illness severity at VAD implant, need for additional right heart support, and presence of congenital heart disease, body size remains an independent predictor of mortality and adverse events on VAD support. Those patients able to accommodate adult-designed implantable continuous-flow VADs experience markedly improved survival outcomes and lower complication rates with improved rehabilitation potential. For the remaining cohort, device choices are limited to extracorporeal VAD support with inferior outcomes and care limited to hospital settings. The deficit in pediatric-specific VAD devices is a well-recognized need to optimize care for this complex cohort.

JHLT OpenVol. 11
Morgan Stanley Children's Hospital (US), Hospital for Sick Children (CA)
Good health and well-being
Openalex Percentile: Top 97%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.