Preparation of a New Inexpensive Paper-Based Sensor for the Detection of Nitrite and Nitrate Species in Water

A low-cost, disposable, paper-based microfluidic analytical device (µPAD) has been developed for the measurement of nitrite and nitrate in water, with a color intensity-based response. The µPAD was fabricated using Whatman filter paper No. 1 and a glossy, self-adhesive backing. Nitrite was measured by the Griess reaction, and for nitrate determination, nitrate was reduced to nitrite in situ on the paper with zinc nanoparticles (ZnNPs). We chose ZnNPs because they outperformed zinc microparticles (ZnMPs). The system showed linear calibration ranges of 0.01−1.25 mM for nitrite and 0.04−1.25 mM for nitrate. The detection limits were 0.003 and 0.008 mM,respectively. The method showed no interference from common ions present in water. The results of real samples were consistent with the spectrophotometric reference method, so the proposed µPAD is suitable for rapid measurement of nitrite/nitrate concentrations at sampling sites of environmental and drinking waters.

Authors

Institutions

Publication Details

Journal
OICC Press Journals
Published
2026-01-04
DOI
https://doi.org/10.57647/inl.2024.1404.13
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of a New Inexpensive Paper-Based Sensor for the Detection of Nitrite and Nitrate Species in Water

Mohammad Joshaghani, Zahra Moradi, Kambiz Varmira, Parvaneh Ghaderi-Shekhi Abadi
OICC Press Journals
Biosensors and Analytical Detection
article

Preparation of a New Inexpensive Paper-Based Sensor for the Detection of Nitrite and Nitrate Species in Water

Mohammad Joshaghani, Zahra Moradi, Kambiz Varmira, Parvaneh Ghaderi-Shekhi Abadi
article en

Abstract

A low-cost, disposable, paper-based microfluidic analytical device (µPAD) has been developed for the measurement of nitrite and nitrate in water, with a color intensity-based response. The µPAD was fabricated using Whatman filter paper No. 1 and a glossy, self-adhesive backing. Nitrite was measured by the Griess reaction, and for nitrate determination, nitrate was reduced to nitrite in situ on the paper with zinc nanoparticles (ZnNPs). We chose ZnNPs because they outperformed zinc microparticles (ZnMPs). The system showed linear calibration ranges of 0.01−1.25 mM for nitrite and 0.04−1.25 mM for nitrate. The detection limits were 0.003 and 0.008 mM,respectively. The method showed no interference from common ions present in water. The results of real samples were consistent with the spectrophotometric reference method, so the proposed µPAD is suitable for rapid measurement of nitrite/nitrate concentrations at sampling sites of environmental and drinking waters.

OICC Press Journals
Razi University (IR), Kermanshah University of Medical Sciences (IR), Jahrom University of Medical Sciences (IR), Alborz University of Medical Sciences (IR)
Clean water and sanitation
Openalex Percentile: Top 97%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies