A Soft-Pneumatic Actuator Array for Tactile Stimulation in Preterm Infants

Preterm infants in neonatal intensive care units (NICUs) experience impaired neurodevelopment and dysregulated stress responses, partly due to a lack of tactile stimulation. Although massage therapy offers proven therapeutic benefits by stimulating C-tactile afferents through (gentle) dynamic touch, existing methods are limited by clinical staff variability and resource constraints. This work presents a compact soft-pneumatic actuator array (SPAA) utilizing four nylon–TPU actuators (modules) connected in series or in parallel to perform a sequential actuation; this array is designed to deliver safe, shear-free, and massage-like normal compression tailored for preterm infants. Actuator performance was characterized using a load-cell and a pressure sensor under different preloads (10–30 g), establishing operating internal pressures of 20–50 kPa, which produced target force ranges between 0.1 and 0.3 N. Two SPAA architectures were evaluated: (i) parallel manifold with branch resistances and (ii) series chain with graded outlet resistances, using passive fluidic sequencing for controlled activation. The series configuration achieved repeatable sequential actuation with programmable delays, essential for mimicking therapeutic massage patterns. These results demonstrate that passive soft-pneumatic sequencing can reliably deliver dynamic tactile stimuli within neurophysiological and safety constraints, laying the groundwork for standardized, automated neonatal massage therapy in NICUs.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2026-01-05
DOI
https://doi.org/10.3390/act15010031
Primary Topic
Infant Development and Preterm Care
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Soft-Pneumatic Actuator Array for Tactile Stimulation in Preterm Infants

Emir A. Vela, Mahdi Tavakoli, Franco Daiji Huemura Okumura, Sebastian Tuesta Pereda
Actuators
Infant Development and Preterm Care
article

A Soft-Pneumatic Actuator Array for Tactile Stimulation in Preterm Infants

Emir A. Vela, Mahdi Tavakoli, Franco Daiji Huemura Okumura, Sebastian Tuesta Pereda
article en

Abstract

Preterm infants in neonatal intensive care units (NICUs) experience impaired neurodevelopment and dysregulated stress responses, partly due to a lack of tactile stimulation. Although massage therapy offers proven therapeutic benefits by stimulating C-tactile afferents through (gentle) dynamic touch, existing methods are limited by clinical staff variability and resource constraints. This work presents a compact soft-pneumatic actuator array (SPAA) utilizing four nylon–TPU actuators (modules) connected in series or in parallel to perform a sequential actuation; this array is designed to deliver safe, shear-free, and massage-like normal compression tailored for preterm infants. Actuator performance was characterized using a load-cell and a pressure sensor under different preloads (10–30 g), establishing operating internal pressures of 20–50 kPa, which produced target force ranges between 0.1 and 0.3 N. Two SPAA architectures were evaluated: (i) parallel manifold with branch resistances and (ii) series chain with graded outlet resistances, using passive fluidic sequencing for controlled activation. The series configuration achieved repeatable sequential actuation with programmable delays, essential for mimicking therapeutic massage patterns. These results demonstrate that passive soft-pneumatic sequencing can reliably deliver dynamic tactile stimuli within neurophysiological and safety constraints, laying the groundwork for standardized, automated neonatal massage therapy in NICUs.

ActuatorsVol. 15(1)
University of Alberta (CA), Universidad de Ingeniería y Tecnología (PE)
University of Alberta
Openalex Percentile: Top 97%
Infant Development and Preterm Care
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.