Impact of Zirconia and Titanium Implant Surfaces of Different Roughness on Oral Epithelial Cells

<b>Background/Objectives</b>: Formation of tight contacts between oral soft tissue and dental implants is a significant challenge in contemporary implantology. An essential role in this process is played by oral epithelial cells. In the present study, we investigated how titanium and zirconia surfaces with different roughness influence various parameters of oral epithelial cells in vitro. <b>Methods</b>: We used the human oral squamous carcinoma Ca9-22 cell line and cultured them on the following surfaces: machined smooth titanium (TiM) and zirconia (ZrM) surfaces, as well as sandblasted and acid-etched titanium moderately rough (SLA) and zirconia (ZLA) surfaces. Cell proliferation/viability was measured by CCK-8 assay, and cell morphology was analyzed by fluorescent microscopy. The gene expression of interleukin (IL)-8, intercellular adhesion molecule (ICAM)-1, E-cadherin, integrin (ITG)-α6, and ITG-β4 was measured by qPCR, and the content of IL-8 in conditioned media by ELISA. <b>Results</b>: At the initial culture phase, cell proliferation was promoted by rougher surfaces. Differences in cell attachment were observed between machined and moderately rough surfaces. Machined surfaces were associated with slightly higher IL-8 levels (<i>p</i> < 0.05). Furthermore, both ZLA and SLA surfaces promoted the expression of (ITG)-α, ITG-β4, and ICAM-1 in Ca9-22 cells (<i>p</i> < 0.05). Surface material had no impact on the investigated parameters. <b>Conclusions</b>: Under the limitations of this in vitro study, some properties of oral epithelial cells, particularly the immunological and barrier function, are moderately modified by roughness but not by material. Hence, the roughness of the implant surface might play a role in the quality of the peri-implant epithelium.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-01-04
DOI
https://doi.org/10.3390/dj14010030
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Zirconia and Titanium Implant Surfaces of Different Roughness on Oral Epithelial Cells

Christian Behm, Zhiwei Tian, Bin Shi, Christian Ulm et al.
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Impact of Zirconia and Titanium Implant Surfaces of Different Roughness on Oral Epithelial Cells

Christian Behm, Zhiwei Tian, Bin Shi, Christian Ulm, Raphael S. Wagner, Benjamin E. Pippenger, Marco Aoqi Rausch, Erwin Jonke, Vera Maierhofer, Oleh Andrukhov, Xiaohui Rausch-Fan
article en

Abstract

<b>Background/Objectives</b>: Formation of tight contacts between oral soft tissue and dental implants is a significant challenge in contemporary implantology. An essential role in this process is played by oral epithelial cells. In the present study, we investigated how titanium and zirconia surfaces with different roughness influence various parameters of oral epithelial cells in vitro. <b>Methods</b>: We used the human oral squamous carcinoma Ca9-22 cell line and cultured them on the following surfaces: machined smooth titanium (TiM) and zirconia (ZrM) surfaces, as well as sandblasted and acid-etched titanium moderately rough (SLA) and zirconia (ZLA) surfaces. Cell proliferation/viability was measured by CCK-8 assay, and cell morphology was analyzed by fluorescent microscopy. The gene expression of interleukin (IL)-8, intercellular adhesion molecule (ICAM)-1, E-cadherin, integrin (ITG)-α6, and ITG-β4 was measured by qPCR, and the content of IL-8 in conditioned media by ELISA. <b>Results</b>: At the initial culture phase, cell proliferation was promoted by rougher surfaces. Differences in cell attachment were observed between machined and moderately rough surfaces. Machined surfaces were associated with slightly higher IL-8 levels (<i>p</i> < 0.05). Furthermore, both ZLA and SLA surfaces promoted the expression of (ITG)-α, ITG-β4, and ICAM-1 in Ca9-22 cells (<i>p</i> < 0.05). Surface material had no impact on the investigated parameters. <b>Conclusions</b>: Under the limitations of this in vitro study, some properties of oral epithelial cells, particularly the immunological and barrier function, are moderately modified by roughness but not by material. Hence, the roughness of the implant surface might play a role in the quality of the peri-implant epithelium.

Dentistry JournalVol. 14(1)
Fujian Medical University (CN), Straumann (Switzerland) (CH), Psychiatry Baselland (CH), First Affiliated Hospital of Fujian Medical University (CN), Medical University of Vienna (AT)
ITI Foundation
Openalex Percentile: Top 97%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.