Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods

Research on the configuration and mechanical performance of arch-column-tie beam joints, which combine features of arch-tie beam joints and tubular joints, remains limited, particularly for long-span structures subjected to heavy loads at high building stories. This study focuses on a joint in an engineering structure comprising a circular arch beam, a square-section inclined column, and a tie beam, where both the arch and the inclined column are concrete-filled steel tube (CFST) members. A novel joint configuration was proposed, then a refined finite element model was established. The joint’s mechanical mechanism and failure mode under axial compression in the arch beam were investigated, considering two conditions: the presence of prestressed high-strength rods and the failure of the rods. Subsequently, a parametric study was conducted to investigate the influence of variations in the web thickness of the tie beam, the steel tube wall thickness of the arched beam, the steel tube wall thickness of the supporting inclined column, and the strength grades of steel and concrete on the bearing capacity behavior and failure modes. Numerical simulation results indicate that the joint remains elastic under the design load for both conditions, meeting the design requirements. The joint reaches its ultimate capacity when extensive yielding occurs in the tie beam along the junction region with the circular arch beam, as well as in the steel tube of the arch beam. At this stage, the steel plates and concrete within the joint zone remain elastic, ensuring reliable load transfer. The maximum computed load of the model with prestressed rods was 2.28 times the design load. The absence of prestressed rods could lead to a significant increase in the high-stress area within the web of the tie beam, decreasing the joint’s stiffness by 12.4% at yielding, but have a limited effect on its maximum bearing capacity. Gradually increasing the wall thickness of the arch beam’s steel tube shifts the failure mode from arch-beam-dominated yielding to tie-beam-dominated yielding along the junction region. Increasing the steel strength grade is more efficient in enhancing the bearing capacity than increasing the concrete strength grade. Finally, a design methodology for the joint zone was established based on three aspects: local stress transfer at the bottom of the arch beam, force equilibrium between the arch beam and the tie beam, and the biaxial compression state of the concrete in the joint zone. Furthermore, the construction process and mechanical analysis methods for various construction stages were proposed.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2026-01-03
DOI
https://doi.org/10.3390/buildings16010216
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods

Zhiliang Zuo, Yuezhou Zhou, Chongyang Li, Xianggang Su et al.
Buildings
Structural Load-Bearing Analysis
article

Mechanical Performance of Joints with Bearing Plates in Concrete-Filled Steel Tubular Arch-Supporting Column-Prestressed Steel Reinforced Concrete Beam Structures: Numerical Simulation and Design Methods

Zhiliang Zuo, Yuezhou Zhou, Chongyang Li, Xianggang Su, Lehua Huang
article en

Abstract

Research on the configuration and mechanical performance of arch-column-tie beam joints, which combine features of arch-tie beam joints and tubular joints, remains limited, particularly for long-span structures subjected to heavy loads at high building stories. This study focuses on a joint in an engineering structure comprising a circular arch beam, a square-section inclined column, and a tie beam, where both the arch and the inclined column are concrete-filled steel tube (CFST) members. A novel joint configuration was proposed, then a refined finite element model was established. The joint’s mechanical mechanism and failure mode under axial compression in the arch beam were investigated, considering two conditions: the presence of prestressed high-strength rods and the failure of the rods. Subsequently, a parametric study was conducted to investigate the influence of variations in the web thickness of the tie beam, the steel tube wall thickness of the arched beam, the steel tube wall thickness of the supporting inclined column, and the strength grades of steel and concrete on the bearing capacity behavior and failure modes. Numerical simulation results indicate that the joint remains elastic under the design load for both conditions, meeting the design requirements. The joint reaches its ultimate capacity when extensive yielding occurs in the tie beam along the junction region with the circular arch beam, as well as in the steel tube of the arch beam. At this stage, the steel plates and concrete within the joint zone remain elastic, ensuring reliable load transfer. The maximum computed load of the model with prestressed rods was 2.28 times the design load. The absence of prestressed rods could lead to a significant increase in the high-stress area within the web of the tie beam, decreasing the joint’s stiffness by 12.4% at yielding, but have a limited effect on its maximum bearing capacity. Gradually increasing the wall thickness of the arch beam’s steel tube shifts the failure mode from arch-beam-dominated yielding to tie-beam-dominated yielding along the junction region. Increasing the steel strength grade is more efficient in enhancing the bearing capacity than increasing the concrete strength grade. Finally, a design methodology for the joint zone was established based on three aspects: local stress transfer at the bottom of the arch beam, force equilibrium between the arch beam and the tie beam, and the biaxial compression state of the concrete in the joint zone. Furthermore, the construction process and mechanical analysis methods for various construction stages were proposed.

BuildingsVol. 16(1)
China Aerospace Science and Industry Corporation (China) (CN), Guangzhou Design Institute (CN), South China University of Technology (CN)
Sustainable cities and communities
Openalex Percentile: Top 97%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.