Geometrical Aberration Correction Method for Computer Radiography System Scanning Devices

The paper describes a practically implemented method for correcting the geometrical aberrations introduced by a scanning device as a proposed stage of the computer radiography system qualification. The presence of geometrical distortions in the scanned images affects the metrological characteristics of the measurement methods and techniques that are using these systems. The method allows for correction of a systematic error obtained when scanning photostimulable phosphor detectors on the digital radiography devices. The main stages of method implementation include fabrication of the calibration sample, conducting reference instrumental measurements, comparing reference measurements with digital image processing results, and estimating and correcting the errors. During the period 2022 to 2024, the examination results for three scanning devices were analyzed. The use of the geometrical aberration correction method allows for minimization of distortions as well as estimation of quality and stability of scanning devices.

Authors

Institutions

Publication Details

Journal
Russian Journal of Nondestructive Testing
Published
2025-10-01
DOI
https://doi.org/10.1134/s1061830925700354
Primary Topic
Digital Radiography and Breast Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Geometrical Aberration Correction Method for Computer Radiography System Scanning Devices

E. O. Kovalev, Yu. M. Ekimov, A. O. Kazak, A. P. Yaskevich et al.
Russian Journal of Nondestructive Testing
Digital Radiography and Breast Imaging
article

Geometrical Aberration Correction Method for Computer Radiography System Scanning Devices

E. O. Kovalev, Yu. M. Ekimov, A. O. Kazak, A. P. Yaskevich, A. V. Sergeev, V. I. Stavrietsky, O. A. Nikitin, M. A. Malyshev
article en

Abstract

The paper describes a practically implemented method for correcting the geometrical aberrations introduced by a scanning device as a proposed stage of the computer radiography system qualification. The presence of geometrical distortions in the scanned images affects the metrological characteristics of the measurement methods and techniques that are using these systems. The method allows for correction of a systematic error obtained when scanning photostimulable phosphor detectors on the digital radiography devices. The main stages of method implementation include fabrication of the calibration sample, conducting reference instrumental measurements, comparing reference measurements with digital image processing results, and estimating and correcting the errors. During the period 2022 to 2024, the examination results for three scanning devices were analyzed. The use of the geometrical aberration correction method allows for minimization of distortions as well as estimation of quality and stability of scanning devices.

Russian Journal of Nondestructive TestingVol. 61(10)
All-Russian Scientific Research Institute of Technical Physics (RU)
Openalex Percentile: Top 26%
Digital Radiography and Breast Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.