Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals

This study evaluates the impact of capillary refill time (CRT) modulation on photoplethysmography (PPG) signals for improved non-invasive continuous blood pressure (CBP) estimation. Data from 21 healthy participants were collected, applying a standardized 9 N pressure for 15 s to induce CRT during 6-min sessions. PPG signals were segmented into 252 paired 30-s intervals (CRT-modulated and standard). Three machine learning models-ResNetCNN, LSTM, and Transformer-were validated using leave-one-subject-out (LOSO) and non-LOSO methods. CRT modulation significantly enhanced accuracy across all models. ResNetCNN showed substantial improvements, reducing mean absolute error (MAE) by up to 35.6% and mean absolute percentage error (MAPE) by up to 40.6%. LSTM and Transformer models also achieved notable accuracy gains. All models met the Association for the Advancement of Medical Instrumentation (AAMI) criteria (mean error < 5 mmHg; standard deviation < 8 mmHg). The findings suggest CRT modulation's strong potential to improve wearable CBP monitoring, especially in resource-limited settings.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-05
DOI
https://doi.org/10.3390/s26010345
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals

Yixiong Chen, Lan Lin, Shen Sun, Dongdong Wang et al.
Sensors
Non-Invasive Vital Sign Monitoring
article

Non-Invasive Blood Pressure Estimation Enhanced by Capillary Refill Time Modulation of PPG Signals

Yixiong Chen, Lan Lin, Shen Sun, Dongdong Wang, Qianheng Yin
article en

Abstract

This study evaluates the impact of capillary refill time (CRT) modulation on photoplethysmography (PPG) signals for improved non-invasive continuous blood pressure (CBP) estimation. Data from 21 healthy participants were collected, applying a standardized 9 N pressure for 15 s to induce CRT during 6-min sessions. PPG signals were segmented into 252 paired 30-s intervals (CRT-modulated and standard). Three machine learning models-ResNetCNN, LSTM, and Transformer-were validated using leave-one-subject-out (LOSO) and non-LOSO methods. CRT modulation significantly enhanced accuracy across all models. ResNetCNN showed substantial improvements, reducing mean absolute error (MAE) by up to 35.6% and mean absolute percentage error (MAPE) by up to 40.6%. LSTM and Transformer models also achieved notable accuracy gains. All models met the Association for the Advancement of Medical Instrumentation (AAMI) criteria (mean error < 5 mmHg; standard deviation < 8 mmHg). The findings suggest CRT modulation's strong potential to improve wearable CBP monitoring, especially in resource-limited settings.

SensorsVol. 26(1)
China Aerospace Science and Technology Corporation (CN), Beijing University of Technology (CN)
Openalex Percentile: Top 97%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.