Numerical and experimental study on the optimization of a ribbed-petaled pattern absorber pipe with spiral twisted tapes enhancements

• The study develops a new absorber tube using passive cooling techniques. • The effect of mass flow rate and geometrical parameters is examined. • A rib pitch of 16 mm, width of 1.75 mm, and height of 0.1 mm are optimal. • The tube using all passive cooling methods achieved a 48.3% THPF increase. • The difference between experimental and numerical results is 3.01%. Low thermal efficiency remains one of the most critical challenges in absorber tube designs. Therefore, Thermohydraulic Performance Factor (THPF) analysis was performed for a newly designed absorber tube featuring ribs and petal arrays on its surfaces. Three key parameters were studied: rib pitch numbers of (8, 10, 12, 14, and 16), rib width (1, 1.25, 1.50, 1.75, and 2) mm, and rib height (0.1, 0.2, 0.3, 0.4, and 0.5) mm. Also, petal arrays are incorporated to enhance thermal performance. Once the effects of geometrical parameters were optimized, the study experimentally revealed the impact of flow enhancers including a coil, a twisted tape, and their combination. The study examined flow rates of (0.01, 0.03, 0.05, and 0.07 kg/s) with a constant heat flux of 1000 W/m². The optimal rib tube geometry was a rib pitch of 16, a rib width of 1.75 mm, and a rib height of 0.1 mm, achieving the highest THPF enhancement of 14.07%. The best-ribbed tube design with petal arrays resulted in 18.79% increase in THPF. The results were experimentally validated, with a variation of 3.01%. Finally, the combination of coiled twisted tape with the best absorber tube design yielded the highest THPF enhancement of 43.80%.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-01-05
DOI
https://doi.org/10.1016/j.rineng.2026.109004
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and experimental study on the optimization of a ribbed-petaled pattern absorber pipe with spiral twisted tapes enhancements

Ali Abdulrazzak Jasim, Hariam Luqman Azeez, Banw Omer Ahmed, Norasikin Ahmad Ludin et al.
Results in Engineering
Solar Thermal and Photovoltaic Systems
article

Numerical and experimental study on the optimization of a ribbed-petaled pattern absorber pipe with spiral twisted tapes enhancements

Ali Abdulrazzak Jasim, Hariam Luqman Azeez, Banw Omer Ahmed, Norasikin Ahmad Ludin, Sharul Sham Dol, Adnan Ibrahim, Mahmoud Jaber, Ahmad Fazlizan
article en

Abstract

• The study develops a new absorber tube using passive cooling techniques. • The effect of mass flow rate and geometrical parameters is examined. • A rib pitch of 16 mm, width of 1.75 mm, and height of 0.1 mm are optimal. • The tube using all passive cooling methods achieved a 48.3% THPF increase. • The difference between experimental and numerical results is 3.01%. Low thermal efficiency remains one of the most critical challenges in absorber tube designs. Therefore, Thermohydraulic Performance Factor (THPF) analysis was performed for a newly designed absorber tube featuring ribs and petal arrays on its surfaces. Three key parameters were studied: rib pitch numbers of (8, 10, 12, 14, and 16), rib width (1, 1.25, 1.50, 1.75, and 2) mm, and rib height (0.1, 0.2, 0.3, 0.4, and 0.5) mm. Also, petal arrays are incorporated to enhance thermal performance. Once the effects of geometrical parameters were optimized, the study experimentally revealed the impact of flow enhancers including a coil, a twisted tape, and their combination. The study examined flow rates of (0.01, 0.03, 0.05, and 0.07 kg/s) with a constant heat flux of 1000 W/m². The optimal rib tube geometry was a rib pitch of 16, a rib width of 1.75 mm, and a rib height of 0.1 mm, achieving the highest THPF enhancement of 14.07%. The best-ribbed tube design with petal arrays resulted in 18.79% increase in THPF. The results were experimentally validated, with a variation of 3.01%. Finally, the combination of coiled twisted tape with the best absorber tube design yielded the highest THPF enhancement of 43.80%.

Results in EngineeringVol. 29
Abu Dhabi University (AE), National University of Malaysia (MY)
Affordable and clean energy
Openalex Percentile: Top 97%
Solar Thermal and Photovoltaic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.