Simultaneous High-Precision <sup>13</sup> C Isotope Ratio Analysis of CO <sub>2</sub> and CH <sub>4</sub> Using an FDM-OA-CEAS Sensor

High-sensitivity measurements of both molecular concentrations and isotope ratios (<sup>13</sup>C/<sup>12</sup>C) of CO<sub>2</sub> and CH<sub>4</sub> are crucial for identifying their sources and tracking their dynamics within the carbon cycle. To achieve high-precision and simultaneous <sup>13</sup>C/<sup>12</sup>C ratio analysis of CO<sub>2</sub> and CH<sub>4</sub>, we developed, to the best of our knowledge for the first time, a sensor system based on frequency-division multiplexed off-axis cavity-enhanced absorption spectroscopy (FDM-OA-CEAS). The system enables concurrent detection of four isotopic species (<sup>12</sup>CO<sub>2</sub>, <sup>13</sup>CO<sub>2</sub>, <sup>12</sup>CH<sub>4</sub>, and <sup>13</sup>CH<sub>4</sub>), allowing direct determination of δ<sup>13</sup>C for both CO<sub>2</sub> and CH<sub>4</sub>. Benefiting from a kilometer-scale effective absorption path length, two pairs of CO<sub>2</sub> and CH<sub>4</sub> isotope absorption lines with relatively weak near-infrared line strengths were selected as sensing targets. Each pair of absorption lines can be acquired in a single laser scan, improving detection efficiency and reducing measurement cost. For the four isotopic species, the detection limits are 0.109 ppm for <sup>12</sup>CO<sub>2</sub>, 0.025 ppb for <sup>13</sup>CO<sub>2</sub>, 0.030 ppb for <sup>12</sup>CH<sub>4</sub>, and 0.008 ppb for <sup>13</sup>CH<sub>4</sub>. Furthermore, the detection sensitivity of δ<sup>13</sup>C reaches 0.0108 ‰ for CO<sub>2</sub> and 0.086 ‰ for CH<sub>4</sub> with an integration time of 720 s and 1200 s. These results demonstrate the system's capability for simultaneous, high-precision isotope analysis, highlighting its potential as a practical analytical chemistry tool for environmental and isotopic studies.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-05
DOI
https://doi.org/10.1021/acs.analchem.5c05460
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simultaneous High-Precision 13 C Isotope Ratio Analysis of CO 2 and CH 4 Using an FDM-OA-CEAS Sensor

Hui Yang, Guangzhen Gao, X.D Sheng, Tingdong Cai et al.
Analytical Chemistry
Spectroscopy and Laser Applications
article

Simultaneous High-Precision 13 C Isotope Ratio Analysis of CO 2 and CH 4 Using an FDM-OA-CEAS Sensor

Hui Yang, Guangzhen Gao, X.D Sheng, Tingdong Cai, Yubing Yang
article en

Abstract

High-sensitivity measurements of both molecular concentrations and isotope ratios (<sup>13</sup>C/<sup>12</sup>C) of CO<sub>2</sub> and CH<sub>4</sub> are crucial for identifying their sources and tracking their dynamics within the carbon cycle. To achieve high-precision and simultaneous <sup>13</sup>C/<sup>12</sup>C ratio analysis of CO<sub>2</sub> and CH<sub>4</sub>, we developed, to the best of our knowledge for the first time, a sensor system based on frequency-division multiplexed off-axis cavity-enhanced absorption spectroscopy (FDM-OA-CEAS). The system enables concurrent detection of four isotopic species (<sup>12</sup>CO<sub>2</sub>, <sup>13</sup>CO<sub>2</sub>, <sup>12</sup>CH<sub>4</sub>, and <sup>13</sup>CH<sub>4</sub>), allowing direct determination of δ<sup>13</sup>C for both CO<sub>2</sub> and CH<sub>4</sub>. Benefiting from a kilometer-scale effective absorption path length, two pairs of CO<sub>2</sub> and CH<sub>4</sub> isotope absorption lines with relatively weak near-infrared line strengths were selected as sensing targets. Each pair of absorption lines can be acquired in a single laser scan, improving detection efficiency and reducing measurement cost. For the four isotopic species, the detection limits are 0.109 ppm for <sup>12</sup>CO<sub>2</sub>, 0.025 ppb for <sup>13</sup>CO<sub>2</sub>, 0.030 ppb for <sup>12</sup>CH<sub>4</sub>, and 0.008 ppb for <sup>13</sup>CH<sub>4</sub>. Furthermore, the detection sensitivity of δ<sup>13</sup>C reaches 0.0108 ‰ for CO<sub>2</sub> and 0.086 ‰ for CH<sub>4</sub> with an integration time of 720 s and 1200 s. These results demonstrate the system's capability for simultaneous, high-precision isotope analysis, highlighting its potential as a practical analytical chemistry tool for environmental and isotopic studies.

Analytical ChemistryVol. 98(2)
Jiangsu Normal University (CN)
Openalex Percentile: Top 97%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.