Research on Power Quality Disturbance Identification by Multi-Scale Feature Fusion

In the context of the convergence of multiple energy systems, the risk of power quality degradation across different stages of energy generation and distribution has become increasingly significant. Accurate identification of power quality disturbances is crucial for improving power quality and ensuring the stable operation of power grids. However, existing disturbance identification methods struggle to balance accuracy and computational efficiency, limiting their applicability in real-time monitoring scenarios. To address this issue, this paper proposes a novel disturbance recognition framework called ST-mRMR-RF. The method first applies the S-transform to convert the time-domain signal into the time-frequency domain. It then extracts spectrum, low-frequency, mid-frequency, and high-frequency components as frequency-domain features from this domain. These are fused with time-domain features to form a multi-scale feature set. To reduce feature redundancy, the Maximum Relevance Minimum Redundancy (mRMR) algorithm is applied to select the optimal feature subset, ensuring maximum category relevance and minimal redundancy. Based on this foundation, four classifiers—Random Forest (RF), Partial Least Squares (PLS), Extreme Learning Machine (ELM), and Convolutional Neural Network (CNN)—are employed for disturbance identification. Experimental results show that the feature subset selected via mRMR reduces the model’s training time by 88.91%. When tested in a white noise environment containing 21 types of power quality disturbance signals, the ST-mRMR-RF method achieves a recognition accuracy of 99.24% at a 20dB signal-to-noise ratio. Overall, this framework demonstrates outstanding performance in noise resistance, classification accuracy, and computational efficiency.

Authors

Institutions

Publication Details

Journal
Big Data and Cognitive Computing
Published
2026-01-05
DOI
https://doi.org/10.3390/bdcc10010018
Citations
1
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
21.93
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Power Quality Disturbance Identification by Multi-Scale Feature Fusion

C. M. Qian, Jingjin Wu, Yunhui Wu, Rongnian Tang et al.
1 citations
Big Data and Cognitive Computing
Power Quality and Harmonics
21.93
article

Research on Power Quality Disturbance Identification by Multi-Scale Feature Fusion

C. M. Qian, Jingjin Wu, Yunhui Wu, Rongnian Tang, Kunsong Wu
article en
1 citations

Abstract

In the context of the convergence of multiple energy systems, the risk of power quality degradation across different stages of energy generation and distribution has become increasingly significant. Accurate identification of power quality disturbances is crucial for improving power quality and ensuring the stable operation of power grids. However, existing disturbance identification methods struggle to balance accuracy and computational efficiency, limiting their applicability in real-time monitoring scenarios. To address this issue, this paper proposes a novel disturbance recognition framework called ST-mRMR-RF. The method first applies the S-transform to convert the time-domain signal into the time-frequency domain. It then extracts spectrum, low-frequency, mid-frequency, and high-frequency components as frequency-domain features from this domain. These are fused with time-domain features to form a multi-scale feature set. To reduce feature redundancy, the Maximum Relevance Minimum Redundancy (mRMR) algorithm is applied to select the optimal feature subset, ensuring maximum category relevance and minimal redundancy. Based on this foundation, four classifiers—Random Forest (RF), Partial Least Squares (PLS), Extreme Learning Machine (ELM), and Convolutional Neural Network (CNN)—are employed for disturbance identification. Experimental results show that the feature subset selected via mRMR reduces the model’s training time by 88.91%. When tested in a white noise environment containing 21 types of power quality disturbance signals, the ST-mRMR-RF method achieves a recognition accuracy of 99.24% at a 20dB signal-to-noise ratio. Overall, this framework demonstrates outstanding performance in noise resistance, classification accuracy, and computational efficiency.

Big Data and Cognitive ComputingVol. 10(1)
Hainan University (CN)
Affordable and clean energy
Openalex Percentile: Top 3%
Power Quality and Harmonics
21.93
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.