One-year outcomes of a novel balloon-expandable valve for severe aortic stenosis
This study evaluated the safety and efficacy of the Renatus transcatheter aortic valve system in treating severe aortic stenosis. This prospective, multicenter, single-arm clinical trial employed a target-value approach. The primary endpoint was the all-cause mortality rate at one year postoperatively, while secondary endpoints included assessments of safety and effectiveness. Safety was measured by the all-cause mortality rate at 30 days, the incidence of major adverse cardiovascular events within one year, and the device success rate. Effectiveness was assessed using transvalvular pressure gradient measurements, the incidence of paravalvular leaks, improvements in New York Heart Association (NYHA) cardiac function classification, and quality of life assessments. The study enrolled 166 patients across 14 national centers between July 2021 and April 2022, with a mean age of 73.9 ± 6.0 years and a median STS risk score of 7.7% (IQR 4.1–8.8). Notably, 58.4% of participants had a bicuspid aortic valve (BAV). Baseline comparisons revealed that BAV patients were marginally younger than tricuspid aortic valve (TAV) patients (median age 73 [IQR 69–77] vs. 74 [IQR 71–79], p = 0.055), with larger annular diameters, greater calcification, and more transverse aortic anatomy. All-cause mortality rates at 30 days and one year postoperatively were 2.5% and 3.7%, while cardiac mortality rates were 1.8% and 3.0%, respectively. Rates of permanent pacemaker implantation at 30 days and one year were 1.8% and 3.0%, respectively. Moderate-to-severe paravalvular leaks were present in 2.5% of patients at 30 days, increasing to 6.6% after one year. Stroke, coronary obstruction, and myocardial infarction incidences remained low, at 0.6%. EuroQol-5 Dimension scores significantly improved from 67.7 ± 18.4 at baseline to 80.0 ± 11.6 and 83.7 ± 10.1 at 30 days and one year, respectively. Patients with NYHA classes I and II rose dramatically from 18.7% at baseline to 99.3% postoperatively. Among selected patients, the Renatus balloon-expandable transcatheter valve system was associated with favorable safety and efficacy outcomes at 1-year post-procedure, regardless of aortic valve leaflet morphology.
Authors
- Yingqiang Guo
- Xiangbin Pan
- Haibo Zhang
- Lai Wei
- Jiangang Wang
- Yuehuan Li
- Liming Liu
- Dongjin Wang
- Liang Ma
- Jianan Wang
Institutions
- Central South University (CN)
- Sun Yat-sen University (CN)
- Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
- Sichuan University (CN)
- Fudan University (CN)
- West China Hospital of Sichuan University (CN)
- Nanjing Drum Tower Hospital (CN)
- Beijing Anzhen Hospital (CN)
- Zhongshan Hospital (CN)
- The First Affiliated Hospital, Sun Yat-sen University (CN)
- Second Affiliated Hospital of Zhejiang University (CN)
- Xiangya Hospital Central South University (CN)
- Fu Wai Hospital (CN)
- First Affiliated Hospital Zhejiang University (CN)
Publication Details
- Journal
- BMC Cardiovascular Disorders
- Published
- 2026-01-05
- DOI
- https://doi.org/10.1186/s12872-025-05472-3
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00