Agarose as a tissue mimic for porcine kidney at the micro-length scale

Agarose gels are frequently utilized to simulate tissue. This study aimed to find an appropriate agarose concentration that matches the mechanical characteristics of pig kidney at the micro length scale and compare these to macro-scale properties. For all agarose samples and porcine kidneys, the shear storage modulus and loss modulus were measured at the micro-length scale using nanoindentation measurements with a 100 μm diameter probe, for frequencies from 10 Hz to 110 Hz. Measurements at the macro-length scale were carried out with a rheometer from 0.1 Hz to a maximum of 9.5 Hz at a shear strain amplitude of 0.1 % and fit to a fractional derivative mechanical model. The storage modulus at the micro-length scale was higher by factor of 1.2-70 than the storage modulus at macro-length scale in kidney samples and agarose (depending on agarose concentration), which was linked to gel and tissue microstructure. An agarose concentration of 1.2 % best fitted the kidney tissue properties at microscale.

Authors

Institutions

Publication Details

Journal
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Published
2026-01-05
DOI
https://doi.org/10.1016/j.jmbbm.2026.107332
Primary Topic
Tissue Engineering and Regenerative Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Agarose as a tissue mimic for porcine kidney at the micro-length scale

Robin O. Cleveland, Aadarsh Mishra, Riaz Akhtar
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials
Tissue Engineering and Regenerative Medicine
article

Agarose as a tissue mimic for porcine kidney at the micro-length scale

Robin O. Cleveland, Aadarsh Mishra, Riaz Akhtar
article en

Abstract

Agarose gels are frequently utilized to simulate tissue. This study aimed to find an appropriate agarose concentration that matches the mechanical characteristics of pig kidney at the micro length scale and compare these to macro-scale properties. For all agarose samples and porcine kidneys, the shear storage modulus and loss modulus were measured at the micro-length scale using nanoindentation measurements with a 100 μm diameter probe, for frequencies from 10 Hz to 110 Hz. Measurements at the macro-length scale were carried out with a rheometer from 0.1 Hz to a maximum of 9.5 Hz at a shear strain amplitude of 0.1 % and fit to a fractional derivative mechanical model. The storage modulus at the micro-length scale was higher by factor of 1.2-70 than the storage modulus at macro-length scale in kidney samples and agarose (depending on agarose concentration), which was linked to gel and tissue microstructure. An agarose concentration of 1.2 % best fitted the kidney tissue properties at microscale.

Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsVol. 176
University of Liverpool (GB), University of Oxford (GB), Science Oxford (GB)
Openalex Percentile: Top 97%
Tissue Engineering and Regenerative Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Agarose as a tissue mimic for porcine kidney at the micro-length scale — Robin O. Cleveland, Aadarsh Mishra, et al. · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2026) | TGRS Research Map | TGRS