Study of Hydraulic Disturbance Transient Processes in Pumped-Storage Power Stations Considering Electro-Mechanical Coupling

Pumped-storage power stations, as a critical resource for supporting secure and stable grid operation, typically adopt a 'single-tunnel-multiple-unit' configuration, where hydraulic disturbance becomes a key operating condition affecting system security. Existing studies have primarily focused on the impact of the hydro-mechanical subsystem on the normally operating units, while the influence of the electrical subsystem on hydraulic disturbance has been insufficiently addressed. To bridge this gap, this study develops a coupled model of a grid-connected pumped-storage power station incorporating a detailed representation of the power system. The model comprehensively captures the multi-domain interactions among the hydraulic, mechanical, electrical, and grid subsystems, and its accuracy is validated using data from a physical model test platform. On this basis, the hydraulic transient responses under two modeling conditions-detailed grid representation and conventional simplified grid modeling-are systematically compared. Key parameters from the hydraulic, mechanical, and electrical domains are further examined to quantify their impacts on the dynamic characteristics of hydraulic disturbance. The results demonstrate that detailed grid modeling reveals novel characteristics of the hydraulic disturbance that cannot be simulated by the conventional model. Under the detailed model, the normally operating units compensate for the power deficit caused by the tripping unit, leading to reduced hydraulic pressure fluctuations and a significant increase in the maximum output of the operating units. Meanwhile, hydro-mechanical parameters strongly influence the transient behaviors of unit output and net head, whereas the guide vane regulation of the operating unit remains predominantly driven by grid-frequency deviations. Overall, this study enhances the understanding of hydraulic disturbance dynamics in grid-connected pumped-storage systems and provides important insights for ensuring their secure and stable operation.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-03
DOI
https://doi.org/10.3390/s26010311
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Hydraulic Disturbance Transient Processes in Pumped-Storage Power Stations Considering Electro-Mechanical Coupling

Chengpeng Liu, Xiuxing Yin, J B Yang, Zhigao Zhao
Sensors
Cavitation Phenomena in Pumps
article

Study of Hydraulic Disturbance Transient Processes in Pumped-Storage Power Stations Considering Electro-Mechanical Coupling

Chengpeng Liu, Xiuxing Yin, J B Yang, Zhigao Zhao
article en

Abstract

Pumped-storage power stations, as a critical resource for supporting secure and stable grid operation, typically adopt a 'single-tunnel-multiple-unit' configuration, where hydraulic disturbance becomes a key operating condition affecting system security. Existing studies have primarily focused on the impact of the hydro-mechanical subsystem on the normally operating units, while the influence of the electrical subsystem on hydraulic disturbance has been insufficiently addressed. To bridge this gap, this study develops a coupled model of a grid-connected pumped-storage power station incorporating a detailed representation of the power system. The model comprehensively captures the multi-domain interactions among the hydraulic, mechanical, electrical, and grid subsystems, and its accuracy is validated using data from a physical model test platform. On this basis, the hydraulic transient responses under two modeling conditions-detailed grid representation and conventional simplified grid modeling-are systematically compared. Key parameters from the hydraulic, mechanical, and electrical domains are further examined to quantify their impacts on the dynamic characteristics of hydraulic disturbance. The results demonstrate that detailed grid modeling reveals novel characteristics of the hydraulic disturbance that cannot be simulated by the conventional model. Under the detailed model, the normally operating units compensate for the power deficit caused by the tripping unit, leading to reduced hydraulic pressure fluctuations and a significant increase in the maximum output of the operating units. Meanwhile, hydro-mechanical parameters strongly influence the transient behaviors of unit output and net head, whereas the guide vane regulation of the operating unit remains predominantly driven by grid-frequency deviations. Overall, this study enhances the understanding of hydraulic disturbance dynamics in grid-connected pumped-storage systems and provides important insights for ensuring their secure and stable operation.

SensorsVol. 26(1)
Wuhan University (CN)
Openalex Percentile: Top 97%
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.