A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics

High impedance faults (HIF) in the resonant grounding system of distribution networks pose significant challenges for traditional protection devices, which often fail to detect and eliminate these faults promptly. The difficulty in setting an appropriate threshold and ensuring reliable detection at low signal-to-noise ratios further complicates the issue. To overcome these limitations, this paper presents a novel approach that analyzes the kurtosis and skewness characteristics of the single-phase high-impedance grounding zero-sequence current waveform, using the Emanuel model as a basis. The proposed method detects HIF based on a kurtosis threshold and pinpoints the faulted line using the skewness coefficient, introducing a more reliable and precise detection technique. Simulation and field tests validate the robustness of this approach, demonstrating strong resistance to noise interference and enhanced fault detection capabilities.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-05
DOI
https://doi.org/10.1038/s41598-025-33118-z
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics

Sheharyar Hussain, Yuan Gao, Ying He, Botong Li et al.
Scientific Reports
Power Systems Fault Detection
article

A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics

Sheharyar Hussain, Yuan Gao, Ying He, Botong Li, Qinglin Meng
article en

Abstract

High impedance faults (HIF) in the resonant grounding system of distribution networks pose significant challenges for traditional protection devices, which often fail to detect and eliminate these faults promptly. The difficulty in setting an appropriate threshold and ensuring reliable detection at low signal-to-noise ratios further complicates the issue. To overcome these limitations, this paper presents a novel approach that analyzes the kurtosis and skewness characteristics of the single-phase high-impedance grounding zero-sequence current waveform, using the Emanuel model as a basis. The proposed method detects HIF based on a kurtosis threshold and pinpoints the faulted line using the skewness coefficient, introducing a more reliable and precise detection technique. Simulation and field tests validate the robustness of this approach, demonstrating strong resistance to noise interference and enhanced fault detection capabilities.

Scientific ReportsVol. 16(1)
Tianjin University (CN), State Grid Corporation of China (China) (CN), Tianjin Research Institute of Electric Science (China) (CN), Zhejiang University (CN)
Science and Technology Project of State Grid
Openalex Percentile: Top 97%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A novel approach for high impedance fault detection in resonant grounding systems based on statistical characteristics — Sheharyar Hussain, Yuan Gao, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS