Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO3-based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO3/carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO3/CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression Ipa = 3.73 [AMXL] + 0.77 with R2 = 0.96 and at 0.1 to 30.0 μM with the linear regression Ipa = 3.76 [AMXL] + 0.69 with R2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM–1 cm–2, respectively. Furthermore, Co-WO3/CPE showed high selectivity and anti-interference capabilities. The sensing and disposable Co-WO3/CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Authors

Institutions

Publication Details

Journal
Industrial & Engineering Chemistry Research
Published
2026-01-05
DOI
https://doi.org/10.1021/acs.iecr.5c03996
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

Yogesh M. Shanbhag, Ashutosh Sharma, Kunal Mondal, Shankara S. Kalanur et al.
Industrial & Engineering Chemistry Research
Electrochemical sensors and biosensors
article

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

Yogesh M. Shanbhag, Ashutosh Sharma, Kunal Mondal, Shankara S. Kalanur, Mahesh M. Shanbhag, Nagaraj P. Shetti, Abdullah N. Alodhayb
article en

Abstract

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO3-based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO3/carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO3/CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression Ipa = 3.73 [AMXL] + 0.77 with R2 = 0.96 and at 0.1 to 30.0 μM with the linear regression Ipa = 3.76 [AMXL] + 0.69 with R2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM–1 cm–2, respectively. Furthermore, Co-WO3/CPE showed high selectivity and anti-interference capabilities. The sensing and disposable Co-WO3/CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Industrial & Engineering Chemistry ResearchVol. 65(1)
Chandigarh University (IN), Idaho State University (US), Oak Ridge National Laboratory (US), King Saud University (SA), KLE Technological University (IN), Hydrogenics (Belgium) (BE), Interface (United Kingdom) (GB), Université du Québec à Trois-Rivières (CA), Indian Institute of Technology Kanpur (IN)
Openalex Percentile: Top 97%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.