Fuzzy Comprehensive State Evaluation Method of Filter Circuit Breaker Based on Field Operation Data

This study focuses on an 800 kV Filter Circuit Breaker (FCB) equipped with phase-controlled closing. The real-time health status of the circuit breaker was evaluated by analyzing the factors influencing its condition based on field-operation data. Key performance parameters, including mechanical characteristics, switching performance, and insulation properties, were employed for the assessment. Furthermore, field operation data are preprocessed to establish a comprehensive database that integrates data from C2-class margin tests, phase-controlled switching tests, and phase-controlled closing factory tests. A combined subjective–objective weighting method is applied to assign weights to health impact factors, and an improved fuzzy comprehensive evaluation method incorporating field operation data is proposed. Based on this evaluation, different operation and maintenance strategies were formulated. The results demonstrate that the proposed method enables a comprehensive and accurate assessment of the health status of FCBs, offering a reliable framework for optimizing condition-based maintenance in practical engineering applications.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-01-04
DOI
https://doi.org/10.3390/en19010264
Primary Topic
Power System Reliability and Maintenance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fuzzy Comprehensive State Evaluation Method of Filter Circuit Breaker Based on Field Operation Data

Fenglong Ma, Jiaying Yu, Liyun Dai, Yousu Qin et al.
Energies
Power System Reliability and Maintenance
article

Fuzzy Comprehensive State Evaluation Method of Filter Circuit Breaker Based on Field Operation Data

Fenglong Ma, Jiaying Yu, Liyun Dai, Yousu Qin, Yongxing Wang, Zhihui Huang, Hui Ni
article en

Abstract

This study focuses on an 800 kV Filter Circuit Breaker (FCB) equipped with phase-controlled closing. The real-time health status of the circuit breaker was evaluated by analyzing the factors influencing its condition based on field-operation data. Key performance parameters, including mechanical characteristics, switching performance, and insulation properties, were employed for the assessment. Furthermore, field operation data are preprocessed to establish a comprehensive database that integrates data from C2-class margin tests, phase-controlled switching tests, and phase-controlled closing factory tests. A combined subjective–objective weighting method is applied to assign weights to health impact factors, and an improved fuzzy comprehensive evaluation method incorporating field operation data is proposed. Based on this evaluation, different operation and maintenance strategies were formulated. The results demonstrate that the proposed method enables a comprehensive and accurate assessment of the health status of FCBs, offering a reliable framework for optimizing condition-based maintenance in practical engineering applications.

EnergiesVol. 19(1)
Electric Power Research Institute (US), State Grid Corporation of China (China) (CN), Dalian University of Technology (CN)
Openalex Percentile: Top 98%
Power System Reliability and Maintenance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.