Multiplatform Benchtop NMR Interlaboratory Study of Model Liquid Dosage Forms of Pharmaceutical Products

Low-field NMR relaxometry uses water proton (<sup>1</sup>H<sub>2</sub>O) relaxation (<i>w</i>NMR) as a powerful and flexible tool to reveal deviations in critical quality attributes of liquid pharmaceuticals such as concentration or, in the case of proteins, aggregation. Measurements are fast and nondestructive, and many benchtop instruments can make measurements noninvasively, with an intact drug vial, prefilled syringe, or pen inserted directly into the probe. Because of the diversity of low-field instrument configurations and operating temperatures, the varying field strengths available, and the many possible protocols, pulse sequences, and parameters for conducting relaxation measurements, we sought to test the reproducibility of <i>w</i>NMR across platforms, and to identify the details of applying <i>w</i>NMR that impact reproducibility. To accomplish this, we piloted an interlaboratory study, in collaboration with benchtop NMR instrument vendors, using model liquid dosage forms of pharmaceutical products in sealed vials. This study demonstrates that when suitable measurement protocols are employed, <i>w</i>NMR measurements from all instruments can track the concentrations of diverse samples with high linearity. Furthermore, <i>w</i>NMR measurements were capable of detecting intentionally included outlier samples. This study revealed various operating procedures and variables that contributed more to measurement variance than any hardware- or instrument-specific differences. Based on these results, we offer initial considerations for harmonizing measurement protocols to enable reliable <i>w</i>NMR analysis of pharmaceuticals.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-01-05
DOI
https://doi.org/10.1021/acs.analchem.5c05487
Primary Topic
NMR spectroscopy and applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiplatform Benchtop NMR Interlaboratory Study of Model Liquid Dosage Forms of Pharmaceutical Products

Katharine T. Briggs, Susanne Riegel, Paul Hui, Matteo Pennestri et al.
Analytical Chemistry
NMR spectroscopy and applications
article

Multiplatform Benchtop NMR Interlaboratory Study of Model Liquid Dosage Forms of Pharmaceutical Products

Katharine T. Briggs, Susanne Riegel, Paul Hui, Matteo Pennestri, Robert G. Brinson, Robert Espina, Leonid Grunin, Thomas Reininger, Frank Delaglio, Luke W. Arbogast, Hèctor Fort Robert, Kevin P. Nott, Brendan Lichtenthal, Innokenty Nikolaev, John P. Marino, Juan F. Araneda, Marc B. Taraban, Y. Bruce Yu
article en

Abstract

Low-field NMR relaxometry uses water proton (<sup>1</sup>H<sub>2</sub>O) relaxation (<i>w</i>NMR) as a powerful and flexible tool to reveal deviations in critical quality attributes of liquid pharmaceuticals such as concentration or, in the case of proteins, aggregation. Measurements are fast and nondestructive, and many benchtop instruments can make measurements noninvasively, with an intact drug vial, prefilled syringe, or pen inserted directly into the probe. Because of the diversity of low-field instrument configurations and operating temperatures, the varying field strengths available, and the many possible protocols, pulse sequences, and parameters for conducting relaxation measurements, we sought to test the reproducibility of <i>w</i>NMR across platforms, and to identify the details of applying <i>w</i>NMR that impact reproducibility. To accomplish this, we piloted an interlaboratory study, in collaboration with benchtop NMR instrument vendors, using model liquid dosage forms of pharmaceutical products in sealed vials. This study demonstrates that when suitable measurement protocols are employed, <i>w</i>NMR measurements from all instruments can track the concentrations of diverse samples with high linearity. Furthermore, <i>w</i>NMR measurements were capable of detecting intentionally included outlier samples. This study revealed various operating procedures and variables that contributed more to measurement variance than any hardware- or instrument-specific differences. Based on these results, we offer initial considerations for harmonizing measurement protocols to enable reliable <i>w</i>NMR analysis of pharmaceuticals.

Analytical ChemistryVol. 98(2)
Oxford Instruments (United Kingdom) (GB), University of Maryland, Baltimore (US), National Institute of Standards and Technology (US), Bruker (United States) (US), Alberta Energy (CA), TECE (Germany) (DE), National Institute of Standards (EG), Research Institute for Bioscience and Biotechnology (NP), Institute for Bioscience and Biotechnology Research
Clean water and sanitation
Openalex Percentile: Top 94%
NMR spectroscopy and applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.