Tip Discharge Evolution Characteristics and Mechanism Analysis via Optical–Electrical Sensors in Oil-Immersed Transformers

Tip discharge in oil-immersed transformers poses a significant threat to insulation integrity. Conventional detection methods, such as gas and electrical analysis, are limited by slow response times or susceptibility to interference. Additionally, the lack of systematic comparisons between aged and fresh oil using multi-modal signal correlations hinders the development of accurate diagnostic strategies. To address this, a multi-modal sensing platform employing optical, UHF, and HFCT sensors, complemented by visual observation, was developed to investigate the evolution characteristics and mechanisms of tip discharge and to compare the detection effectiveness of these methods. Experimental results reveal that aged oil undergoes a novel four-stage evolution, where discharge signals first rise to a local peak, then experience suppression, followed by a dramatic surge, and finally decline slightly before breakdown. This process is governed by an "Impurity-Assisted Cumulative Breakdown Mechanism," driven by impurity bridge growth and space charge effects, with signal transitions from 'decoupling' to synchronization. The optical sensor demonstrated superior sensitivity in early discharge stages compared to electrical methods. In contrast, fresh oil exhibited a "High-Field-Driven Stochastic Breakdown Mechanism," with isolated pulses from micro-bubble discharges maintaining a metastable state until a critical threshold triggers instantaneous failure. This study enhances the understanding of how oil condition alters discharge mechanisms and underscores the value of multi-modal sensing for insulation condition assessment.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-01-04
DOI
https://doi.org/10.3390/s26010331
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tip Discharge Evolution Characteristics and Mechanism Analysis via Optical–Electrical Sensors in Oil-Immersed Transformers

Fenghua. Wang, Bing Xue, Zehao Chen, Chengxiang Liu et al.
Sensors
Power Transformer Diagnostics and Insulation
article

Tip Discharge Evolution Characteristics and Mechanism Analysis via Optical–Electrical Sensors in Oil-Immersed Transformers

Fenghua. Wang, Bing Xue, Zehao Chen, Chengxiang Liu, Gehao Sheng, Yong Qian, Chunhui Zhang
article en

Abstract

Tip discharge in oil-immersed transformers poses a significant threat to insulation integrity. Conventional detection methods, such as gas and electrical analysis, are limited by slow response times or susceptibility to interference. Additionally, the lack of systematic comparisons between aged and fresh oil using multi-modal signal correlations hinders the development of accurate diagnostic strategies. To address this, a multi-modal sensing platform employing optical, UHF, and HFCT sensors, complemented by visual observation, was developed to investigate the evolution characteristics and mechanisms of tip discharge and to compare the detection effectiveness of these methods. Experimental results reveal that aged oil undergoes a novel four-stage evolution, where discharge signals first rise to a local peak, then experience suppression, followed by a dramatic surge, and finally decline slightly before breakdown. This process is governed by an "Impurity-Assisted Cumulative Breakdown Mechanism," driven by impurity bridge growth and space charge effects, with signal transitions from 'decoupling' to synchronization. The optical sensor demonstrated superior sensitivity in early discharge stages compared to electrical methods. In contrast, fresh oil exhibited a "High-Field-Driven Stochastic Breakdown Mechanism," with isolated pulses from micro-bubble discharges maintaining a metastable state until a critical threshold triggers instantaneous failure. This study enhances the understanding of how oil condition alters discharge mechanisms and underscores the value of multi-modal sensing for insulation condition assessment.

SensorsVol. 26(1)
Shanghai Jiao Tong University (CN), Hubei Provincial Water Resources and Hydropower Planning Survey and Design Institute (CN)
Openalex Percentile: Top 98%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.