Clinical significance of machine learning algorithm in predicting PPM during TAVR in small annuli

Compared with left heart catheterization (LHC), the pressure gradient of an aortic valve (PG<sub>AV</sub>) measured by echocardiography during transcatheter aortic valve replacement (TAVR) in small annuli is overestimated. The purpose of this study was to improve the accuracy of PG<sub>AV</sub> measurements by echocardiography in small annuli and to evaluate the influence of PG<sub>AV</sub> on prognosis. The internal derivation cohort included 273 consecutive patients with aortic stenosis and a small annulus (computed tomographic scan showing an annulus circumference < 72 mm or area < 400 mm<sup>2</sup>) who underwent TAVR. Patients completed transthoracic echocardiography (TTE) and LHC measurements during TAVR, and an extreme gradient boosting (XGBoost) algorithm was trained. The primary outcome was a composite end point of all-cause mortality and readmission for heart failure. The mean PG<sub>AV</sub> level measured by TTE was overestimated compared to the LHC measurement {52.5 [interquartile range: 47.5-57.0] mmHg vs. 42.5 (interquartile range: 38.0-46.0) mmHg, P < 0.001}. After adjustments to the XGBoost, the mean PG<sub>AV</sub> measured by TTE could be significantly improved [Pearson correlation coefficient = 0.94, P < 0.001]. Importantly, patients with a predicted mean PG<sub>AV</sub> ≥ 68.6 mmHg showed a significantly increased incidence of composite end points at 2 years after the procedures (40.7% vs. 16.0%, P < 0.001). The XGBoost model could effectively improve the accuracy of the mean PG<sub>AV</sub> measured by TTE during TAVR, and the predicted mean increase in the PG<sub>AV</sub> level may lead to a worse prognosis.Clinical Trial Registration: ClinicalTrials.gov Protocol Registration System (NCT05044338).

Authors

Institutions

Publication Details

Journal
Cardiovascular Intervention and Therapeutics
Published
2026-01-05
DOI
https://doi.org/10.1007/s12928-025-01215-5
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical significance of machine learning algorithm in predicting PPM during TAVR in small annuli

W. W. L. Li, Yingqiang Guo, F. Chen, MengEn Zhai et al.
Cardiovascular Intervention and Therapeutics
Cardiac Valve Diseases and Treatments
article

Clinical significance of machine learning algorithm in predicting PPM during TAVR in small annuli

W. W. L. Li, Yingqiang Guo, F. Chen, MengEn Zhai, Yu Mao, Xiangbin Pan, Gejun Zhang, Yongjian Wu, Jian Liu, Ping Jin, Yuhui Yang, Jian Yang, Yang Liu
article en

Abstract

Compared with left heart catheterization (LHC), the pressure gradient of an aortic valve (PG<sub>AV</sub>) measured by echocardiography during transcatheter aortic valve replacement (TAVR) in small annuli is overestimated. The purpose of this study was to improve the accuracy of PG<sub>AV</sub> measurements by echocardiography in small annuli and to evaluate the influence of PG<sub>AV</sub> on prognosis. The internal derivation cohort included 273 consecutive patients with aortic stenosis and a small annulus (computed tomographic scan showing an annulus circumference < 72 mm or area < 400 mm<sup>2</sup>) who underwent TAVR. Patients completed transthoracic echocardiography (TTE) and LHC measurements during TAVR, and an extreme gradient boosting (XGBoost) algorithm was trained. The primary outcome was a composite end point of all-cause mortality and readmission for heart failure. The mean PG<sub>AV</sub> level measured by TTE was overestimated compared to the LHC measurement {52.5 [interquartile range: 47.5-57.0] mmHg vs. 42.5 (interquartile range: 38.0-46.0) mmHg, P < 0.001}. After adjustments to the XGBoost, the mean PG<sub>AV</sub> measured by TTE could be significantly improved [Pearson correlation coefficient = 0.94, P < 0.001]. Importantly, patients with a predicted mean PG<sub>AV</sub> ≥ 68.6 mmHg showed a significantly increased incidence of composite end points at 2 years after the procedures (40.7% vs. 16.0%, P < 0.001). The XGBoost model could effectively improve the accuracy of the mean PG<sub>AV</sub> measured by TTE during TAVR, and the predicted mean increase in the PG<sub>AV</sub> level may lead to a worse prognosis.Clinical Trial Registration: ClinicalTrials.gov Protocol Registration System (NCT05044338).

Cardiovascular Intervention and TherapeuticsVol. 41(2)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Sichuan University (CN), West China Hospital of Sichuan University (CN), Xi'an Medical University (CN), Guangdong Provincial People's Hospital (CN), Xijing Hospital (CN), Xi'an Jiaotong University (CN)
Good health and well-being
Openalex Percentile: Top 98%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.