Multi-parameter, kHz rate spectrally resolved NO PLIF in a supersonic jet

Quantitative, high-bandwidth measurements of temperature, pressure, and velocity are needed to characterize high-speed flows and validate numerical simulations. To that end, this work demonstrates rapid, multi-parameter spectrally resolved planar laser-induced fluorescence (SR-PLIF) for spatially resolved, calibration-free measurements of these three key quantities using the gamma-bands of nitric oxide near 225.33 nm. The SR-PLIF technique was validated from 295-420 K and 3.48-20.4 kPa using a static gas cell and exhibits an average temperature and pressure error of 2% and 4%, respectively. The diagnostic was then used to study an underexpanded jet at rates up to 1 kHz and a spatial resolution of 220µm, with results showing favorable agreement with numerical simulations.

Authors

Institutions

Publication Details

Journal
Optics Letters
Published
2026-01-05
DOI
https://doi.org/10.1364/ol.582048
Primary Topic
Combustion and flame dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-parameter, kHz rate spectrally resolved NO PLIF in a supersonic jet

Christopher L. Strand, Spencer C. Barnes, Sean Clees, Joshua A. Vandervort et al.
Optics Letters
Combustion and flame dynamics
article

Multi-parameter, kHz rate spectrally resolved NO PLIF in a supersonic jet

Christopher L. Strand, Spencer C. Barnes, Sean Clees, Joshua A. Vandervort, Jin A Lee, Ronald Hanson
article en

Abstract

Quantitative, high-bandwidth measurements of temperature, pressure, and velocity are needed to characterize high-speed flows and validate numerical simulations. To that end, this work demonstrates rapid, multi-parameter spectrally resolved planar laser-induced fluorescence (SR-PLIF) for spatially resolved, calibration-free measurements of these three key quantities using the gamma-bands of nitric oxide near 225.33 nm. The SR-PLIF technique was validated from 295-420 K and 3.48-20.4 kPa using a static gas cell and exhibits an average temperature and pressure error of 2% and 4%, respectively. The diagnostic was then used to study an underexpanded jet at rates up to 1 kHz and a spatial resolution of 220µm, with results showing favorable agreement with numerical simulations.

Optics LettersVol. 51(4)
Stanford University (US)
Openalex Percentile: Top 97%
Combustion and flame dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.