A Novel Technique for Quality Control of Microinjection Molding

In the microinjection molding process, continuous monitoring is important for optimization of the process and control. In microfluidic or lab-on-chip devices, defective microfeatures can compromise biological assays and diagnostic results, and therefore, the quality of these features is a critical issue. Microfeatures can be inspected using advanced inspection and microscopic techniques, but these are expensive, time-consuming, and difficult to use for full-scale production. We present here a new technique for quality control of microfeatures, which uses the filling of a controlled microcavity inside or outside the molded part as a quality control tool for filling microfeatures. Micro gaps (checkpoints) are used as an indicator of microfeature filling. Two micro gaps can be used for filling (checkpoints) as a Go/No-Go gauge.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2026-01-05
DOI
https://doi.org/10.3390/mi17010074
Citations
1
Primary Topic
Nanofabrication and Lithography Techniques
Type
article
Field-Weighted Citation Impact
21.28
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Technique for Quality Control of Microinjection Molding

Abdel Naser Daoud, Zulfiqur Ali, Atef M. Ghaleb, Ali Abdelhafeez Hassan
1 citations
Micromachines
Nanofabrication and Lithography Techniques
21.28
article

A Novel Technique for Quality Control of Microinjection Molding

Abdel Naser Daoud, Zulfiqur Ali, Atef M. Ghaleb, Ali Abdelhafeez Hassan
article en
1 citations

Abstract

In the microinjection molding process, continuous monitoring is important for optimization of the process and control. In microfluidic or lab-on-chip devices, defective microfeatures can compromise biological assays and diagnostic results, and therefore, the quality of these features is a critical issue. Microfeatures can be inspected using advanced inspection and microscopic techniques, but these are expensive, time-consuming, and difficult to use for full-scale production. We present here a new technique for quality control of microfeatures, which uses the filling of a controlled microcavity inside or outside the molded part as a quality control tool for filling microfeatures. Micro gaps (checkpoints) are used as an indicator of microfeature filling. Two micro gaps can be used for filling (checkpoints) as a Go/No-Go gauge.

MicromachinesVol. 17(1)
Alfaisal University (SA), University of Cumbria (GB)
Openalex Percentile: Top 4%
Nanofabrication and Lithography Techniques
21.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.