BeatMapSeq: A Framework for In‐Line Beat‐Based Cardiac Parametric Mapping Sequence Construction and Map Building

This study aims to propose a framework, named BeatMapSeq, designed to simplify the sequence construction and map building for cardiac parametric mapping in cardiovascular magnetic resonance. BeatMapSeq comprises two components: the BeatMap Framework and DeepFittingNet. BeatMap Framework is a general framework for cardiac beat-based parametric mapping sequences, enabling interactive construction of various cardiac parametric mapping sequences directly on the scanner without the need for programming. DeepFittingNet is a neural network designed for automated in-line map generation for various parametric mapping sequences. BeatMapSeq was validated on Philips 3.0-T scanners through in vivo studies. Numerous cardiac parametric mapping sequences were tested, including T<sub>1</sub> mapping with inversion and saturation preparation, T<sub>2</sub> mapping with 2D and 3D coverage, T<sub>1</sub>rho mapping, and simultaneous T<sub>1</sub>/T<sub>2</sub> mapping. The in-line map-building ability was further validated on an additional cohort of healthy volunteers, and the performance of map building was compared with the nonlinear least-squares (NLS) curve-fitting method. With BeatMapSeq, all testing sequences were interactively constructed on the scanner without programming and successfully applied to all volunteers. BeatMapSeq's MOLLI implementation showed excellent agreement with the corresponding vendor-provided product. DeepFittingNet generated the corresponding maps fully automatically, without any user intervention, and the in-line map-building capability of BeatMapSeq enabled the parametric maps to be available on the scanner shortly after imaging. DeepFittingNet demonstrated good agreement with the NLS curve-fitting method for T<sub>1</sub>, T<sub>2</sub>, and T<sub>1</sub>rho calculations. The in vivo T<sub>1</sub>, T<sub>2</sub>, and T<sub>1</sub>rho measured at 3.0 T in this study were consistent with the previously reported values obtained using the corresponding sequences. The proposed BeatMapSeq streamlined the sequence construction and map building for cardiac parametric mapping in cardiovascular magnetic resonance.

Authors

Institutions

Publication Details

Journal
NMR in Biomedicine
Published
2026-01-04
DOI
https://doi.org/10.1002/nbm.70223
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BeatMapSeq: A Framework for In‐Line Beat‐Based Cardiac Parametric Mapping Sequence Construction and Map Building

Zhensen Chen, Dongyue Si, He Ding, Xiaoying Tang et al.
NMR in Biomedicine
Advanced MRI Techniques and Applications
article

BeatMapSeq: A Framework for In‐Line Beat‐Based Cardiac Parametric Mapping Sequence Construction and Map Building

Zhensen Chen, Dongyue Si, He Ding, Xiaoying Tang, Jing Xiao, Peng Wu, Rui Guo
article en

Abstract

This study aims to propose a framework, named BeatMapSeq, designed to simplify the sequence construction and map building for cardiac parametric mapping in cardiovascular magnetic resonance. BeatMapSeq comprises two components: the BeatMap Framework and DeepFittingNet. BeatMap Framework is a general framework for cardiac beat-based parametric mapping sequences, enabling interactive construction of various cardiac parametric mapping sequences directly on the scanner without the need for programming. DeepFittingNet is a neural network designed for automated in-line map generation for various parametric mapping sequences. BeatMapSeq was validated on Philips 3.0-T scanners through in vivo studies. Numerous cardiac parametric mapping sequences were tested, including T<sub>1</sub> mapping with inversion and saturation preparation, T<sub>2</sub> mapping with 2D and 3D coverage, T<sub>1</sub>rho mapping, and simultaneous T<sub>1</sub>/T<sub>2</sub> mapping. The in-line map-building ability was further validated on an additional cohort of healthy volunteers, and the performance of map building was compared with the nonlinear least-squares (NLS) curve-fitting method. With BeatMapSeq, all testing sequences were interactively constructed on the scanner without programming and successfully applied to all volunteers. BeatMapSeq's MOLLI implementation showed excellent agreement with the corresponding vendor-provided product. DeepFittingNet generated the corresponding maps fully automatically, without any user intervention, and the in-line map-building capability of BeatMapSeq enabled the parametric maps to be available on the scanner shortly after imaging. DeepFittingNet demonstrated good agreement with the NLS curve-fitting method for T<sub>1</sub>, T<sub>2</sub>, and T<sub>1</sub>rho calculations. The in vivo T<sub>1</sub>, T<sub>2</sub>, and T<sub>1</sub>rho measured at 3.0 T in this study were consistent with the previously reported values obtained using the corresponding sequences. The proposed BeatMapSeq streamlined the sequence construction and map building for cardiac parametric mapping in cardiovascular magnetic resonance.

NMR in BiomedicineVol. 39(2)
Beijing Institute of Technology (CN), Army Medical University (CN), Fudan University (CN), Shanghai Institute for Science of Science (CN), Philips (China) (CN), Xinqiao Hospital (CN), Shanghai Center for Brain Science and Brain-Inspired Technology (CN), Tsinghua University (CN)
Openalex Percentile: Top 98%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.