Experimental and Numerical Evaluation of the Impact of Hemi‐Circular Fins Number on Thermal Performances of a Double‐Pass Solar Air Heater

ABSTRACT Solar air heaters often suffer from limited thermal performance due to weak turbulence and low convective heat transfer inside the duct. To overcome this limitation, an experimental and numerical investigation was carried out on a double‐pass solar air heater (DPSAH). The system was equipped with hemi‐circular fins (HCF) attached to the absorber plate to increase the heat‐transfer surface and enhance flow mixing. Several configurations were analyzed and compared with a conventional SAH. Experimental tests were performed under real climatic conditions in the Gabès region, Tunisia. In addition, a numerical model was developed using ANSYS Fluent to simulate heat transfer and fluid‐flow behavior. Furthermore, the k–ε turbulence model and the discrete ordinates (DO) radiation model were adopted. Thus, the numerical predictions showed good agreement with the experimental results with an average deviation of 4%. Subsequently, five configurations, arranged as 3 × 3, 4 × 3, 3 × 4, 4 × 4, and 4 × 5, were investigated. The results demonstrated that the maximum outlet air temperature reached 80°C for the configuration 4 × 5 fins, while it remained below 73.5°C for the smooth duct. The thermal efficiency increased from 68% for the smooth duct to a maximum of 81% for the 4 × 5 configuration. The thermohydraulic efficiency also improved, reaching 76.1% in the configuration with 4 × 5 fins compared to 67.7% for the smooth case. However, the pressure drop increased to 325 Pa for the 4 × 5 arrangement, while it remained below 4 Pa for the smooth duct. Ultimately, HCF fins provide a simple and effective enhancement of DPSAH efficiency.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2026-01-04
DOI
https://doi.org/10.1002/htj.70159
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and Numerical Evaluation of the Impact of Hemi‐Circular Fins Number on Thermal Performances of a Double‐Pass Solar Air Heater

Saif Ali Kadhim, Ali Habeeb Askar, Walid Ben Amara, Abdallah Bouabidi et al.
Heat Transfer
Heat Transfer Mechanisms
article

Experimental and Numerical Evaluation of the Impact of Hemi‐Circular Fins Number on Thermal Performances of a Double‐Pass Solar Air Heater

Saif Ali Kadhim, Ali Habeeb Askar, Walid Ben Amara, Abdallah Bouabidi, Djamel Sahel, Rami Belguith, Hiba Chmengui
article en

Abstract

ABSTRACT Solar air heaters often suffer from limited thermal performance due to weak turbulence and low convective heat transfer inside the duct. To overcome this limitation, an experimental and numerical investigation was carried out on a double‐pass solar air heater (DPSAH). The system was equipped with hemi‐circular fins (HCF) attached to the absorber plate to increase the heat‐transfer surface and enhance flow mixing. Several configurations were analyzed and compared with a conventional SAH. Experimental tests were performed under real climatic conditions in the Gabès region, Tunisia. In addition, a numerical model was developed using ANSYS Fluent to simulate heat transfer and fluid‐flow behavior. Furthermore, the k–ε turbulence model and the discrete ordinates (DO) radiation model were adopted. Thus, the numerical predictions showed good agreement with the experimental results with an average deviation of 4%. Subsequently, five configurations, arranged as 3 × 3, 4 × 3, 3 × 4, 4 × 4, and 4 × 5, were investigated. The results demonstrated that the maximum outlet air temperature reached 80°C for the configuration 4 × 5 fins, while it remained below 73.5°C for the smooth duct. The thermal efficiency increased from 68% for the smooth duct to a maximum of 81% for the 4 × 5 configuration. The thermohydraulic efficiency also improved, reaching 76.1% in the configuration with 4 × 5 fins compared to 67.7% for the smooth case. However, the pressure drop increased to 325 Pa for the 4 × 5 arrangement, while it remained below 4 Pa for the smooth duct. Ultimately, HCF fins provide a simple and effective enhancement of DPSAH efficiency.

Heat Transfer
University of Technology - Iraq (IQ), University of Miskolc (HU), Université des Sciences et de la Technologie d'Oran Mohamed Boudiaf (DZ), Université d'Artois (FR), Amar Telidji University of Laghouat (DZ), University of Gabès (TN)
Climate action
Openalex Percentile: Top 98%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.