Real time intraoperative detection of residual breast cancer using active thermal imaging

Margin-negative (R0) resection is highly important for long-term survival, with reduced mortality and morbidity in breast cancer patients. Palpation and visual inspection, as well as the current intraoperative imaging techniques are insufficient for discriminating between healthy and malignant tissue types, often leading to margin-positive (R1) resections. This study introduces an active thermal imaging system that enables real-time intraoperative detection of residual cancer via dynamic thermal response patterns. A prototype integrating an infrared heating system and a high-resolution thermal imaging camera coupled with a data transformation algorithm was developed. Freshly resected breast cancer specimens were analyzed to determine thermal dissipation differences between R0 and R1 resections by correlating them with histopathological reports. The transformed data were passed through a decision tree model to determine the cutoff values of relevant thermal parameters. After the operating parameters were finalized and the safety standards were met, the system was implemented real-time during breast cancer surgeries in willing patients to determine intraoperative cutoffs. Two derived thermal parameters, v(si) of R₁₂ʺ and v(si) of R₁₃ʺ, representing the thermal decay behavior across two adjacent cooling intervals were identified as significant predictors of margin-positive (R1) or margin-negative (R0) resection (p < 0.001). Cutoff values of 68.42 for $$\:\text{v}\left({\text{s}}_{\text{i}}\right)$$ of $$\:{\text{R}}_{12}^{"}$$ and 71.43 for $$\:\text{v}\left({\text{s}}_{\text{i}}\right)$$ of $$\:{\text{R}}_{13}^{"}$$ were established for intraoperative decision-making. The optimized decision tree model using these variables achieved a classification accuracy of 93.33%, with sensitivity of 92.00% and specificity of 94.44% during intraoperative breast cancer surgery. The proposed active thermal imaging system provides a novel, real-time, contrast-free solution for intraoperative cancer detection. Its demonstrated reliability, automation, and ease of integration into surgical workflows may position it as a promising tool for enhancing surgical precision and improving oncological outcomes.

Authors

Institutions

Publication Details

Journal
Discover Imaging.
Published
2026-01-04
DOI
https://doi.org/10.1007/s44352-025-00022-1
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real time intraoperative detection of residual breast cancer using active thermal imaging

Apurba Kumar Santra, Subhasish Sarkar, Ritabrata Saha, Arkadeep Datta et al.
Discover Imaging.
Infrared Thermography in Medicine
article

Real time intraoperative detection of residual breast cancer using active thermal imaging

Apurba Kumar Santra, Subhasish Sarkar, Ritabrata Saha, Arkadeep Datta, U. Garain, Arka Ghosh, Ranjan Ganguly, Avishek Dutta, Rudrajit Majumder
article en

Abstract

Margin-negative (R0) resection is highly important for long-term survival, with reduced mortality and morbidity in breast cancer patients. Palpation and visual inspection, as well as the current intraoperative imaging techniques are insufficient for discriminating between healthy and malignant tissue types, often leading to margin-positive (R1) resections. This study introduces an active thermal imaging system that enables real-time intraoperative detection of residual cancer via dynamic thermal response patterns. A prototype integrating an infrared heating system and a high-resolution thermal imaging camera coupled with a data transformation algorithm was developed. Freshly resected breast cancer specimens were analyzed to determine thermal dissipation differences between R0 and R1 resections by correlating them with histopathological reports. The transformed data were passed through a decision tree model to determine the cutoff values of relevant thermal parameters. After the operating parameters were finalized and the safety standards were met, the system was implemented real-time during breast cancer surgeries in willing patients to determine intraoperative cutoffs. Two derived thermal parameters, v(si) of R₁₂ʺ and v(si) of R₁₃ʺ, representing the thermal decay behavior across two adjacent cooling intervals were identified as significant predictors of margin-positive (R1) or margin-negative (R0) resection (p < 0.001). Cutoff values of 68.42 for $$\:\text{v}\left({\text{s}}_{\text{i}}\right)$$ of $$\:{\text{R}}_{12}^{"}$$ and 71.43 for $$\:\text{v}\left({\text{s}}_{\text{i}}\right)$$ of $$\:{\text{R}}_{13}^{"}$$ were established for intraoperative decision-making. The optimized decision tree model using these variables achieved a classification accuracy of 93.33%, with sensitivity of 92.00% and specificity of 94.44% during intraoperative breast cancer surgery. The proposed active thermal imaging system provides a novel, real-time, contrast-free solution for intraoperative cancer detection. Its demonstrated reliability, automation, and ease of integration into surgical workflows may position it as a promising tool for enhancing surgical precision and improving oncological outcomes.

Discover Imaging.Vol. 3(1)
Jadavpur University (IN), College of Medicine & Sagore Dutta Hospital (IN), Indian Statistical Institute (IN)
Science and Engineering Research Board
Reduced inequalities
Openalex Percentile: Top 98%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.