Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan.

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach.

Publication Details

Journal
PubMed
Published
2026-01-02
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan.

PubMed
Advanced X-ray and CT Imaging
article

Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan.

article en

Abstract

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach.

PubMed
Good health and well-being
Openalex Percentile: Top 98%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.