Femoral Bone Mineral Density Shows Stronger Correlation With Pedicle Screw Insertional Torque than Lumbar Bone Mineral Density or Hounsfield Units: A Retrospective in Vivo Study

ObjectivesInstrumentation failure remains a significant complication in spinal surgery. Preoperative bone health assessment is critical prior to spinal fusion surgery. Currently, bone mineral density (BMD) and Hounsfield Unit (HU) are common preoperative assessments, although it remains unclear which is more predictive of screw fixation strength. We aimed to identify the most reliable preoperative evaluation method for predicting screw insertional torque in patients undergoing lumbar fusion surgery.MethodsPatients who underwent lumbar fusion surgery utilizing pedicle screws between 2021 and 2023, were prospectively registered in our database. All participants underwent preoperative lumbar CT and Dual-Energy X-ray Absorptiometry (DEXA) scans. We analyzed data from 109 patients who underwent lumbar fusion surgery with 6.5 mm pedicle screws. Preoperative BMD was measured via DEXA (lumbar spine and femur), and HU values were obtained from preoperative lumbar CT scans. Insertional torque of the screws was measured intraoperatively using a calibrated torque wrench. Correlations between insertional torque and BMD/HU as well as patients' demographic/lab data were analyzed.ResultsA total of 335 pedicle screws were analyzed. Femoral BMD exhibited the strongest correlation with insertional torque (r = 0.557, <i>P</i> < 0.001), compared with lumbar BMD and HU. Age, ASA grade, BMI, serum calcium, and albumin showed weak correlations.ConclusionsFemoral BMD demonstrated the strongest, although still moderate, association with intraoperative insertional torque among all preoperative bone quality measures evaluated, suggesting that it may offer a more informative estimate of underlying bone strength in patients undergoing lumbar fusion.

Authors

Institutions

Publication Details

Journal
Global Spine Journal
Published
2026-01-03
DOI
https://doi.org/10.1177/21925682251415346
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Femoral Bone Mineral Density Shows Stronger Correlation With Pedicle Screw Insertional Torque than Lumbar Bone Mineral Density or Hounsfield Units: A Retrospective in Vivo Study

Kenta Fujimura, Keisuke Otsuka, Yuichiro Nishiyama, Yoji Ogura et al.
Global Spine Journal
Spinal Fractures and Fixation Techniques
article

Femoral Bone Mineral Density Shows Stronger Correlation With Pedicle Screw Insertional Torque than Lumbar Bone Mineral Density or Hounsfield Units: A Retrospective in Vivo Study

Kenta Fujimura, Keisuke Otsuka, Yuichiro Nishiyama, Yoji Ogura, Arya Varthi, Yoshihisa Suzuki, Taisei Kato
article en

Abstract

ObjectivesInstrumentation failure remains a significant complication in spinal surgery. Preoperative bone health assessment is critical prior to spinal fusion surgery. Currently, bone mineral density (BMD) and Hounsfield Unit (HU) are common preoperative assessments, although it remains unclear which is more predictive of screw fixation strength. We aimed to identify the most reliable preoperative evaluation method for predicting screw insertional torque in patients undergoing lumbar fusion surgery.MethodsPatients who underwent lumbar fusion surgery utilizing pedicle screws between 2021 and 2023, were prospectively registered in our database. All participants underwent preoperative lumbar CT and Dual-Energy X-ray Absorptiometry (DEXA) scans. We analyzed data from 109 patients who underwent lumbar fusion surgery with 6.5 mm pedicle screws. Preoperative BMD was measured via DEXA (lumbar spine and femur), and HU values were obtained from preoperative lumbar CT scans. Insertional torque of the screws was measured intraoperatively using a calibrated torque wrench. Correlations between insertional torque and BMD/HU as well as patients' demographic/lab data were analyzed.ResultsA total of 335 pedicle screws were analyzed. Femoral BMD exhibited the strongest correlation with insertional torque (r = 0.557, <i>P</i> < 0.001), compared with lumbar BMD and HU. Age, ASA grade, BMI, serum calcium, and albumin showed weak correlations.ConclusionsFemoral BMD demonstrated the strongest, although still moderate, association with intraoperative insertional torque among all preoperative bone quality measures evaluated, suggesting that it may offer a more informative estimate of underlying bone strength in patients undergoing lumbar fusion.

Global Spine Journal
Atrium Health Wake Forest Baptist (US), Yale University (US), Tachikawa Hospital (JP)
Openalex Percentile: Top 98%
Spinal Fractures and Fixation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.