Measuring light exposure in nursing home residents with dementia: facility-level measures vs wearable sensor

Abstract Adequate lighting exposure has positive impacts on circadian health, mood, and behavioral symptoms in people with dementia. However, nursing home (NH) residents with dementia often experience insufficient circadian lighting exposure. Increasing research has investigated lighting interventions in this population with mixed results. Most intervention studies evaluated outcomes based on facility-level lighting measures without considering the individual’s actual light exposure. However, light exposures can vary widely between residents, depending on room location, personal behavior, and daily routine. Wearable light sensors allow us to quantify the dosage each individual receives more precisely. This study examined the differences in light intensity (lux) between facility-level and individual-level measures among NH residents with ADRD. The facility-level measure was conducted twice a week in the bedroom, hallway, and dining room, tailored based on individuals’ routines. Individual lighting exposure was measured using a wearable light sensor, LYS button, worn on residents’ shoulder/collar 24 hours/day continuously for one week. Descriptive statistics and paired t-tests were performed. A total of 29 residents (average age: 87 years; 72.4% female) were recruited from two NHs. The average facility-level lighting intensities from the two NHs were 110, 114, and 85 lux in the bedroom, hallway, and dining room, respectively. In contrast, residents’ individual lighting exposure averaged 268 lux. Paired t-tests revealed significant differences between facility-level manual measures and the individual wearable sensor in the bedroom, hallway, dining room, and the overall facility (p < 0.001). Future research should consider using individual light sensors for a more precise design and evaluation of lighting interventions.

Authors

Institutions

Publication Details

Journal
Innovation in Aging
Published
2025-12-01
DOI
https://doi.org/10.1093/geroni/igaf122.3289
Primary Topic
Circadian rhythm and melatonin
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measuring light exposure in nursing home residents with dementia: facility-level measures vs wearable sensor

Ying-Ling Jao, Light Obioma Ndurue, Diane Berish, Marie P. Boltz et al.
Innovation in Aging
Circadian rhythm and melatonin
article

Measuring light exposure in nursing home residents with dementia: facility-level measures vs wearable sensor

Ying-Ling Jao, Light Obioma Ndurue, Diane Berish, Marie P. Boltz, Margaret Calkins, Julian Wang, Yun-Han Kuan, Yo-Jen Liao
article en

Abstract

Abstract Adequate lighting exposure has positive impacts on circadian health, mood, and behavioral symptoms in people with dementia. However, nursing home (NH) residents with dementia often experience insufficient circadian lighting exposure. Increasing research has investigated lighting interventions in this population with mixed results. Most intervention studies evaluated outcomes based on facility-level lighting measures without considering the individual’s actual light exposure. However, light exposures can vary widely between residents, depending on room location, personal behavior, and daily routine. Wearable light sensors allow us to quantify the dosage each individual receives more precisely. This study examined the differences in light intensity (lux) between facility-level and individual-level measures among NH residents with ADRD. The facility-level measure was conducted twice a week in the bedroom, hallway, and dining room, tailored based on individuals’ routines. Individual lighting exposure was measured using a wearable light sensor, LYS button, worn on residents’ shoulder/collar 24 hours/day continuously for one week. Descriptive statistics and paired t-tests were performed. A total of 29 residents (average age: 87 years; 72.4% female) were recruited from two NHs. The average facility-level lighting intensities from the two NHs were 110, 114, and 85 lux in the bedroom, hallway, and dining room, respectively. In contrast, residents’ individual lighting exposure averaged 268 lux. Paired t-tests revealed significant differences between facility-level manual measures and the individual wearable sensor in the bedroom, hallway, dining room, and the overall facility (p < 0.001). Future research should consider using individual light sensors for a more precise design and evaluation of lighting interventions.

Innovation in AgingVol. 9(Supplement_2)
Pennsylvania State University (US), Far Eastern Memorial Hospital (TW), Cleveland Heights University Heights Public Library (US)
Openalex Percentile: Top 36%
Circadian rhythm and melatonin
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.