Clinical and radiographic outcomes of double-triangle locking compression plate (DT-LCP) versus T-shaped locking compression plate (T-LCP) in medial open-wedge high tibial osteotomy: a follow-up study of over 5 years

This study demonstrates that both DT-LCP and T-LCP achieve favorable clinical outcomes after OWHTO, as evidenced by significant reductions in mean VAS scores and improvements in WOMAC and Lysholm ratings. The two fixation systems provide reliable correction in both the coronal and sagittal planes, with good alignment of lower-limb parameters such as HKA and MPTA, showing excellent durability and safety. Satisfactory functional results were obtained with either implant. However, the DT-LCP group demonstrated superior peri-operative performance, with a significantly lower incidence of implant-related irritation, thereby reducing the need for secondary hardware removal and resulting in a lighter economic burden.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Surgery and Research
Published
2026-01-03
DOI
https://doi.org/10.1186/s13018-025-06507-3
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical and radiographic outcomes of double-triangle locking compression plate (DT-LCP) versus T-shaped locking compression plate (T-LCP) in medial open-wedge high tibial osteotomy: a follow-up study of over 5 years

Jinli Chen, Yue Jiang, Haifeng Li, Li Zhang et al.
Journal of Orthopaedic Surgery and Research
Total Knee Arthroplasty Outcomes
article

Clinical and radiographic outcomes of double-triangle locking compression plate (DT-LCP) versus T-shaped locking compression plate (T-LCP) in medial open-wedge high tibial osteotomy: a follow-up study of over 5 years

Jinli Chen, Yue Jiang, Haifeng Li, Li Zhang, Cui Wang, Xia Zhao, Kuishuai Xu, Yu Ning, Tianrui Wang, Huiying Zhou, Xiaodong Jia, Yingze Zhang
article en

Abstract

This study demonstrates that both DT-LCP and T-LCP achieve favorable clinical outcomes after OWHTO, as evidenced by significant reductions in mean VAS scores and improvements in WOMAC and Lysholm ratings. The two fixation systems provide reliable correction in both the coronal and sagittal planes, with good alignment of lower-limb parameters such as HKA and MPTA, showing excellent durability and safety. Satisfactory functional results were obtained with either implant. However, the DT-LCP group demonstrated superior peri-operative performance, with a significantly lower incidence of implant-related irritation, thereby reducing the need for secondary hardware removal and resulting in a lighter economic burden.

Journal of Orthopaedic Surgery and ResearchVol. 21(1)
Qingdao University (CN), Affiliated Hospital of Qingdao University (CN)
Openalex Percentile: Top 98%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Clinical and radiographic outcomes of double-triangle locking compression plate (DT-LCP) versus T-shaped locking compression plate (T-LCP) in medial open-wedge high tibial osteotomy: a follow-up study of over 5 years — Jinli Chen, Yue Jiang, et al. · Journal of Orthopaedic Surgery and Research (2026) | TGRS Research Map | TGRS