Effectiveness of dilution ventilation in mitigating occupational exposure to volatile organic compounds (VOCs) at the breathing zone of nail technicians: a simulation study

Volatile Organic Compounds (VOCs) from nail products pose potential health risks to technicians and clients. The present study investigates the exposure of nail technicians to VOC and assesses the effectiveness of dilution ventilation in mitigating these exposures. A test chamber was configured to simulate a nail salon environment, where three common activities were performed: applying nail polish, removing nail extensions, and nail extension application. A MultiRae Lite gas meter was used to monitor VOC concentrations in the technicians' breathing zones and the ambient environment under both non-ventilated and dilution-ventilated conditions. The average VOC concentrations in the technicians' breathing zones were measured at 8.3 (± 8.576) ppm, 116.2 (± 120.04) ppm, and 29.73 (± 7.876) ppm during nail polish application, nail extension removal, and nail extension application, respectively (n = 30 measured over 15 min). For the same activities, the average ambient VOC concentrations in the non-ventilated chamber were 25.03 (± 13.006) ppm, 192.17 (± 114.900) ppm, and 40.90 (± 30.891) ppm. These concentrations were significantly lowered by dilution ventilation to 0.93 (± 0.179) ppm, 12.6 (± 5.21) ppm, and 2.63 (± 0.812) ppm. For all three activities, a t-test verified a statistically significant drop in VOC concentration with dilution ventilation (p < 0.001). Additionally, the study discovered that VOC emissions could be reduced by over 65% at an air change rate (ACH) of 10 per hour. The results indicate that dilution ventilation can significantly decrease VOC exposure; nonetheless, the study concludes that it is insufficient as the sole control strategy in nail salons because concentrations failed to reach the limit levels, even at the highest tested ACH (100 ACH). This research provides a new scientific perspective on ventilation as a means of controlling occupational exposure to VOC in nail salons.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-01-03
DOI
https://doi.org/10.1038/s41598-025-33777-y
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of dilution ventilation in mitigating occupational exposure to volatile organic compounds (VOCs) at the breathing zone of nail technicians: a simulation study

Samaneh Salari, Ali Karimi, Sahar Fazeli-Tabar, Marjan Fazlali
Scientific Reports
Indoor Air Quality and Microbial Exposure
article

Effectiveness of dilution ventilation in mitigating occupational exposure to volatile organic compounds (VOCs) at the breathing zone of nail technicians: a simulation study

Samaneh Salari, Ali Karimi, Sahar Fazeli-Tabar, Marjan Fazlali
article en

Abstract

Volatile Organic Compounds (VOCs) from nail products pose potential health risks to technicians and clients. The present study investigates the exposure of nail technicians to VOC and assesses the effectiveness of dilution ventilation in mitigating these exposures. A test chamber was configured to simulate a nail salon environment, where three common activities were performed: applying nail polish, removing nail extensions, and nail extension application. A MultiRae Lite gas meter was used to monitor VOC concentrations in the technicians' breathing zones and the ambient environment under both non-ventilated and dilution-ventilated conditions. The average VOC concentrations in the technicians' breathing zones were measured at 8.3 (± 8.576) ppm, 116.2 (± 120.04) ppm, and 29.73 (± 7.876) ppm during nail polish application, nail extension removal, and nail extension application, respectively (n = 30 measured over 15 min). For the same activities, the average ambient VOC concentrations in the non-ventilated chamber were 25.03 (± 13.006) ppm, 192.17 (± 114.900) ppm, and 40.90 (± 30.891) ppm. These concentrations were significantly lowered by dilution ventilation to 0.93 (± 0.179) ppm, 12.6 (± 5.21) ppm, and 2.63 (± 0.812) ppm. For all three activities, a t-test verified a statistically significant drop in VOC concentration with dilution ventilation (p < 0.001). Additionally, the study discovered that VOC emissions could be reduced by over 65% at an air change rate (ACH) of 10 per hour. The results indicate that dilution ventilation can significantly decrease VOC exposure; nonetheless, the study concludes that it is insufficient as the sole control strategy in nail salons because concentrations failed to reach the limit levels, even at the highest tested ACH (100 ACH). This research provides a new scientific perspective on ventilation as a means of controlling occupational exposure to VOC in nail salons.

Scientific ReportsVol. 16(1)
University of Science and Culture (IR), Tehran University of Medical Sciences (IR)
Tehran University of Medical Sciences and Health Services
Openalex Percentile: Top 99%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.