A systematic review and meta-analysis: robotic versus laparoscopic hiatal hernia repair, is there a difference in Clavien Dindo score?
Robotic hiatal hernia repair shows less intraoperative complications in comparison to laparoscopic repair. With the current available literature, no difference in Clavien Dindo score 3 is seen. To investigate the full potential of robotic surgery, prospective studies should be performed with surgeons who have passed their learning curve. Subgroup analyses regarding giant hiatal hernia and redo surgery should be performed. A uniform definition of 'giant' hiatal hernia is needed.
Authors
- Yves Van Nieuwenhove (ORCID: https://orcid.org/0000-0003-3064-5638)
- Ada Mathys
- Elke Van Daele (ORCID: https://orcid.org/0000-0003-0336-4179)
- H. Vanommeslaeghe
Institutions
- Ghent University Hospital (BE)
Publication Details
- Journal
- Acta chirurgica Belgica
- Published
- 2026-01-02
- DOI
- https://doi.org/10.1080/00015458.2025.2611452
- Primary Topic
- Gastroesophageal reflux and treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00