The Radon Effective Dose Calculation Following the Dosimetric Approach: Examples and Challenges

With the ICRP Publication 137 dealing with the occupational intake of radionuclides, an important and crucial path toward the practical implementation of the dosimetric approach also for radon was undertaken. However, some problems and difficulties must be overcome to use this new method to estimate the effective dose of radon in real situations. Direct dosimetric calculations are often not an easy task. The ICRP Publication 137 gives some examples of this new approach by providing the coefficients of the effective dose per exposure for some typical workplaces. In this work, some practical examples of the effective dose calculation in some selected workplaces were performed, studying the most important factors affecting the results. In particular, the role of the equilibrium factor F and of the dose conversion factor (DCF) as a function of the particulate size distribution were investigated and discussed. In this context, a few direct measurements of the equilibrium factor F were done as well as an experimental supporting tool for a comprehensive dose assessment.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-12-23
DOI
https://doi.org/10.1097/hp.0000000000002108
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Radon Effective Dose Calculation Following the Dosimetric Approach: Examples and Challenges

Enrico Chiaberto, Massimo Faure Ragani, Mauro Magnoni
Health Physics
Radioactivity and Radon Measurements
article

The Radon Effective Dose Calculation Following the Dosimetric Approach: Examples and Challenges

Enrico Chiaberto, Massimo Faure Ragani, Mauro Magnoni
article en

Abstract

With the ICRP Publication 137 dealing with the occupational intake of radionuclides, an important and crucial path toward the practical implementation of the dosimetric approach also for radon was undertaken. However, some problems and difficulties must be overcome to use this new method to estimate the effective dose of radon in real situations. Direct dosimetric calculations are often not an easy task. The ICRP Publication 137 gives some examples of this new approach by providing the coefficients of the effective dose per exposure for some typical workplaces. In this work, some practical examples of the effective dose calculation in some selected workplaces were performed, studying the most important factors affecting the results. In particular, the role of the equilibrium factor F and of the dose conversion factor (DCF) as a function of the particulate size distribution were investigated and discussed. In this context, a few direct measurements of the equilibrium factor F were done as well as an experimental supporting tool for a comprehensive dose assessment.

Health PhysicsVol. 130(2)
Advanced Research Projects Agency - Energy (US)
Openalex Percentile: Top 29%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.